Logic Pro User Guide for iPad
- What’s new in Logic Pro 1.1
-
- What is Logic Pro?
- Working areas
- Work with function buttons
- Work with numeric values
-
- Intro to tracks
- Create tracks
- Create tracks using drag and drop
- Choose the default region type for a software instrument track
- Select tracks
- Duplicate tracks
- Reorder tracks
- Rename tracks
- Change track icons
- Change track colors
- Use the tuner on an audio track
- Show the output track in the Tracks area
- Delete tracks
- Edit track parameters
- Start a Logic Pro subscription
- How to get help
-
- Intro to recording
-
- Before recording software instruments
- Record software instruments
- Record additional software instrument takes
- Record to multiple software instrument tracks
- Record multiple MIDI devices to multiple tracks
- Record software instruments and audio simultaneously
- Merge software instrument recordings
- Spot erase software instrument recordings
- Replace software instrument recordings
- Capture your most recent MIDI performance
- Use the metronome
- Use the count-in
-
- Intro to arranging
-
- Intro to regions
- Select regions
- Cut, copy, and paste regions
- Move regions
- Remove gaps between regions
- Delay region playback
- Trim regions
- Loop regions
- Repeat regions
- Mute regions
- Split and join regions
- Stretch regions
- Separate a MIDI region by note pitch
- Bounce regions in place
- Change the gain of audio regions
- Create regions in the Tracks area
- Convert a MIDI region to a Drummer region or a pattern region
- Rename regions
- Change the color of regions
- Delete regions
- Create fades on audio regions
- Access mixing functions using the Fader
-
- Intro to Step Sequencer
- Use Step Sequencer with Drum Machine Designer
- Record Step Sequencer patterns live
- Step record Step Sequencer patterns
- Load and save patterns
- Modify pattern playback
- Edit steps
- Edit rows
- Edit Step Sequencer pattern, row, and step settings in the inspector
- Customize Step Sequencer
-
- Effect plug-ins overview
-
- Instrument plug-ins overview
-
- ES2 overview
- Interface overview
-
- Modulation overview
-
- Vector Envelope overview
- Use Vector Envelope points
- Use Vector Envelope solo and sustain points
- Set Vector Envelope segment times
- Vector Envelope XY pad controls
- Vector Envelope Actions menu
- Vector Envelope loop controls
- Vector Envelope release phase behavior
- Vector Envelope point transition shapes
- Use Vector Envelope time scaling
- Use the Mod Pad
- Modulation source reference
- Via modulation source reference
-
- Sample Alchemy overview
- Interface overview
- Add source material
- Save a preset
- Edit mode
- Play modes
- Source overview
- Synthesis modes
- Granular controls
- Additive effects
- Additive effect controls
- Spectral effect
- Spectral effect controls
- Filter module
- Low and highpass filter
- Comb PM filter
- Downsampler filter
- FM filter
- Envelope generators
- Mod Matrix
- Modulation routing
- Motion mode
- Trim mode
- More menu
- Sampler
- Copyright
ChromaVerb main controls in Logic Pro for iPad
The main section contains the most commonly used ChromaVerb parameters.
ChromaVerb main parameters
Room Type pop-up menu: Choose the type of reverb space you want to recreate. See ChromaVerb room types.
Freeze button: Turn on to recirculate the signal infinitely inside the chosen room type.
Predelay knob and field: Set the time between the start of the original signal and the arrival of the early reflections. You can also tap the field to enter a value in the numeric keypad. Double tap to reset to the default value.
A short predelay setting tends to push sounds away and longer predelay settings tend to bring sounds more to the forefront.
An extremely short predelay setting can color the sound and make it difficult to pinpoint the position of the signal source. A very long predelay setting can be perceived as an unnatural echo and can divorce the original signal from its early reflections, leaving an audible gap between them. An optimal predelay setting depends on the type of input signal—or more precisely, the envelope of the input signal. Percussive signals generally require shorter predelays than signals where the attack fades in gradually. A good working method is to use the longest possible Predelay value before you start to hear side effects, such as an audible echo. When you reach this point, reduce the Predelay setting slightly.
Predelay Sync button: Turn on to restrict Predelay values to divisions synchronized with the host application tempo.
Decay Time knob and field: Set the decay time. The decay for certain frequencies is dependent on damping parameter values. You can also tap the field to enter a value in the numeric keypad. Double tap to reset to the default value.
Decay Time Sync button: Turn on to restrict Decay values to divisions synchronized with the host application tempo.
Attack knob and field: Set the attack phase of the reverb. This affects either the volume or the density build-up time, depending on the chosen room type. You can also tap the field to enter a value in the numeric keypad. Double tap to reset to the default value.
For the following room types the Attack parameter increases volume over time: Theatre, Dense Room, Smooth Space, Reflective Hall, Strange Room, Airy.
For the following room types the Attack parameter sets the amount of time it takes for the reverb to reach the maximum density value, determined with the Density knob: Room, Chamber, Concert Hall, Synth Hall, Digital, Dark Room, Vocal Hall, Bloomy.
Size knob and field: Determine the dimensions of the room. Higher values correspond to a larger space. You can also tap the field to enter a value in the numeric keypad. Double tap to reset to the default value.
Density knob and field: Adjust the density of the early and late reflections simultaneously, depending on room type. You can also tap the field to enter a value in the numeric keypad. Double tap to reset to the default value.
Distance knob and field: Set the perceived distance from the source by altering early and late energy. You can also tap the field to enter a value in the numeric keypad. Double tap to reset to the default value.
Dry control and field: Independently set the level of the source signal. You can also tap the field to enter a value in the numeric keypad. Double tap to reset to the default value.
Wet control and field: Independently set the level of the effect signal. You can also tap the field to enter a value in the numeric keypad. Double tap to reset to the default value.
Download this guide: PDF