Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 1997 Dec;41(12):2686-92.
doi: 10.1128/AAC.41.12.2686.

Flow cytometric analysis of herpes simplex virus type 1 susceptibility to acyclovir, ganciclovir, and foscarnet

Affiliations

Flow cytometric analysis of herpes simplex virus type 1 susceptibility to acyclovir, ganciclovir, and foscarnet

I Pavić et al. Antimicrob Agents Chemother. 1997 Dec.

Abstract

We established a quantitative flow cytometric method for determination of herpes simplex virus type 1 (HSV-1) susceptibility to acyclovir (ACV), ganciclovir, and foscarnet in vitro. Susceptibility was defined in terms of the drug concentration which reduced the number of cells expressing HSV-1 glycoprotein C (gpC) with a fluorescence intensity of > or =10(2) by 50% (IC50). Flow cytometry allowed us to use a high (1.0) as well as a low (0.005) multiplicity of infection, and determination of the IC50 was possible after one or more viral replicative cycles. IC50s were dependent on virus input and on time postinfection. In mixture experiments, 1 to 2% resistant viruses added to a sensitive strain could be detected. The results obtained by flow cytometry showed a good qualitative correlation with those achieved by cytopathic effect inhibitory assay. However, flow cytometry might detect more quantitative differences in drug susceptibility, especially among resistant strains, as confirmed also by determination of intracellular drug phosphorylation. The mean IC50s for ACV-sensitive strains were 0.45 to 1.47 microM, and those for ACV-resistant strains were between 140 and 3,134 microM. Flow cytometric analysis was fast and accurate, automatizable, and highly reproducible. Flow cytometry may be a more powerful tool than standard cytopathic effect-based assays and could have advantages for the detection of low levels of drug resistance or mixtures of sensitive and resistant virus strains.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Antiviral Res. 1983 Nov;3(4):223-34 - PubMed
    1. Antimicrob Agents Chemother. 1983 Sep;24(3):370-4 - PubMed
    1. J Biol Stand. 1986 Jul;14(3):201-11 - PubMed
    1. J Virol. 1987 Jan;61(1):104-12 - PubMed
    1. Antimicrob Agents Chemother. 1987 Jun;31(6):946-8 - PubMed

Publication types

LinkOut - more resources