Malaria diagnosis by field workers using an immunochromatographic test
- PMID: 9373631
- DOI: 10.1016/s0035-9203(97)90254-6
Malaria diagnosis by field workers using an immunochromatographic test
Abstract
A rapid immunodiagnostic test (ICT Malaria PfTest) has been developed by ICT Diagnostics (Sydney, Australia) for the diagnosis of Plasmodium falciparum infection. The test is an antigen capture assay based on the detection of P. falciparum histidine-rich protein 2 in peripheral blood. This study was undertaken to assess the performance and usefulness of the test as a diagnostic method in highly malarious, inaccessible forested villages of Mandla district, central India. In all, 353 patients with fever were scanned by the test in parallel with thick blood film examination. The sensitivity and specificity were 100% and 84.5%, respectively. The whole test took about 5 min. The test results became negative in most cases (70%) within 7 d after initiation of curative chemotherapy. The test is simple, easy to learn and accurate, and may prove to be an important tool in the battle against falciparum malaria.
Similar articles
-
A rapid immunochromatographic test (ICT) for diagnosis of Plasmodium falciparum.Diagn Microbiol Infect Dis. 1998 Apr;30(4):257-60. doi: 10.1016/s0732-8893(98)00003-0. Diagn Microbiol Infect Dis. 1998. PMID: 9582585
-
The ParaSight-F dipstick test as a routine diagnostic tool for malaria in Sri Lanka.Trans R Soc Trop Med Hyg. 1997 Jul-Aug;91(4):398-402. doi: 10.1016/s0035-9203(97)90255-8. Trans R Soc Trop Med Hyg. 1997. PMID: 9373632
-
The use of a dipstick antigen-capture assay for the diagnosis of Plasmodium falciparum infection in a remote forested area of central India.Am J Trop Med Hyg. 1997 Feb;56(2):188-91. doi: 10.4269/ajtmh.1997.56.188. Am J Trop Med Hyg. 1997. PMID: 9080879
-
Diagnosis of malaria by detection of Plasmodium falciparum HRP-2 antigen with a rapid dipstick antigen-capture assay.Lancet. 1994 Mar 5;343(8897):564-8. doi: 10.1016/s0140-6736(94)91520-2. Lancet. 1994. PMID: 7906328
-
Clinical trials of a new immunochromatographic test for diagnosis of Plasmodium falciparum malaria in Goa.Indian J Malariol. 1996 Dec;33(4):166-72. Indian J Malariol. 1996. PMID: 9125830 Clinical Trial.
Cited by
-
Rapid diagnosis of vivax malaria by the SD Bioline Malaria Antigen test when thrombocytopenia is present.J Clin Microbiol. 2008 Mar;46(3):939-42. doi: 10.1128/JCM.02110-07. Epub 2007 Dec 26. J Clin Microbiol. 2008. PMID: 18160449 Free PMC article.
-
An assessment of the usefulness of a rapid immuno-chromatographic test, "Determine trade mark malaria pf" in evaluation of intervention measures in forest villages of central India.BMC Infect Dis. 2001;1:10. doi: 10.1186/1471-2334-1-10. Epub 2001 Aug 14. BMC Infect Dis. 2001. PMID: 11532200 Free PMC article.
-
Comparison of two commercial assays with expert microscopy for confirmation of symptomatically diagnosed malaria.J Clin Microbiol. 2002 Dec;40(12):4675-8. doi: 10.1128/JCM.40.12.4675-4678.2002. J Clin Microbiol. 2002. PMID: 12454171 Free PMC article.
-
Comparison of different methods for delayed post-mortem diagnosis of falciparum malaria.Malar J. 2009 Oct 28;8:244. doi: 10.1186/1475-2875-8-244. Malar J. 2009. PMID: 19863789 Free PMC article.
-
Accuracy of an Immunochromatographic Diagnostic Test (ICT Malaria Combo Cassette Test) Compared to Microscopy among under Five-Year-Old Children when Diagnosing Malaria in Equatorial Guinea.Malar Res Treat. 2010;2010:858427. doi: 10.4061/2010/858427. Epub 2010 Aug 4. Malar Res Treat. 2010. PMID: 22332024 Free PMC article.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources