The sensitive detection and quantitation of antibody to HCV by using a microsphere-based immunoassay and flow cytometry
- PMID: 9332816
The sensitive detection and quantitation of antibody to HCV by using a microsphere-based immunoassay and flow cytometry
Abstract
Antibody to HCV core and NS3 was quantified by using a microsphere immunoassay and flow cytometry. Antibody to core and NS3 was elevated in the 85 seropositive blood donors tested. The amount of either antibody varied over two logs although greater variation was seen with the antibody to NS3 than was seen with antibody to core. In three documented acute HCV cases, the microsphere assay detected antibody prior to antibody detection using the reference methods. Twenty donor samples were indeterminate by the reference methods: 45% of these were indeterminate with the microsphere assay while 25% were negative and 30% were positive. As compared to enzyme immunoassay the microsphere assay showed a 5-fold increase in sensitivity. The microsphere assay demonstrated increased sensitivity for the quantification of specific antibody to HCV core and NS3 and was useful in resolving a significant proportion of indeterminate samples.
Similar articles
-
Quantitative antibody responses to structural (Core) and nonstructural (NS3, NS4, and NS5) hepatitis C virus proteins among seroconverting injecting drug users: impact of epitope variation and relationship to detection of HCV RNA in blood.Hepatology. 1999 Apr;29(4):1288-98. doi: 10.1002/hep.510290442. Hepatology. 1999. PMID: 10094977
-
Performance characteristics of a microsphere immunoassay using recombinant HCV proteins as a confirmatory assay for the detection of antibodies to the hepatitis C virus.Cytometry A. 2005 Oct;67(2):97-103. doi: 10.1002/cyto.a.20163. Cytometry A. 2005. PMID: 16163691
-
Use of overlapping synthetic peptides to characterize samples from blood donors with indeterminate results to hepatitis C virus core antigen.Vox Sang. 1998;75(1):32-6. Vox Sang. 1998. PMID: 9745151
-
Proteomic profiles by multiplex microsphere suspension array.J Immunol Methods. 2018 Oct;461:1-14. doi: 10.1016/j.jim.2018.07.002. Epub 2018 Jul 10. J Immunol Methods. 2018. PMID: 30003895 Review.
-
The immunological assay of drugs.Pharmacol Rev. 1977 Jun;29(2):103-84. Pharmacol Rev. 1977. PMID: 353828 Review. No abstract available.
Cited by
-
Applications of flow cytometry to clinical microbiology.Clin Microbiol Rev. 2000 Apr;13(2):167-95. doi: 10.1128/CMR.13.2.167. Clin Microbiol Rev. 2000. PMID: 10755996 Free PMC article. Review.
-
Flow cytometric microsphere-based immunoassay: analysis of secreted cytokines in whole-blood samples from asthmatics.Clin Diagn Lab Immunol. 2001 Jul;8(4):776-84. doi: 10.1128/CDLI.8.4.776-784.2001. Clin Diagn Lab Immunol. 2001. PMID: 11427426 Free PMC article.
-
Holographic molecular binding assays.Sci Rep. 2020 Feb 6;10(1):1932. doi: 10.1038/s41598-020-58833-7. Sci Rep. 2020. PMID: 32029807 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Other Literature Sources
Research Materials