Maintenance of proximal cortical bone with use of a less stiff femoral component in hemiarthroplasty of the hip without cement. An investigation in a canine model at six months and two years
- PMID: 9314401
- DOI: 10.2106/00004623-199709000-00013
Maintenance of proximal cortical bone with use of a less stiff femoral component in hemiarthroplasty of the hip without cement. An investigation in a canine model at six months and two years
Abstract
A canine model of hemiarthroplasty of the hip was used to determine if the use of a less stiff femoral stem can reduce the amount of bone loss induced by stress-shielding. Two types of stem were used: the stiffer stems were made of a titanium alloy, and the less stiff stems were composed of a cobalt-chromium-alloy core with an outer polymer layer. The stems were identical in shape, and both types were circumferentially coated along their entire length (except for the distal five millimeters) with commercially pure titanium fiber metal. Ten dogs with each type of stem were followed for six months, and twelve dogs with each type of stem were followed for two years. Loss of cortical bone from the proximal part of the femur was associated with both types of stem, but typically 50 per cent less bone was lost with the less stiff implants. Most of the cortical loss occurred at the subperiosteal surface. The amount of medullary bone adjacent to the proximal and distal aspects of both types of stem increased; the less stiff stems were associated with a greater increase in the proximal region, and the stiffer stems were associated with a greater increase in the distal region. Similarly, there were peaks in the amount of bone growth into the proximal and distal portions of both types of stem, with a greater peak in proximal bone growth into the less stiff stems and a greater peak in distal bone growth into the stiffer stems.
Similar articles
-
Effect of flexibility of the femoral stem on bone-remodeling and fixation of the stem in a canine total hip arthroplasty model without cement.J Bone Joint Surg Am. 1999 Jan;81(1):93-107. J Bone Joint Surg Am. 1999. PMID: 9973059
-
The effect of stem stiffness on femoral bone resorption after canine porous-coated total hip arthroplasty.Clin Orthop Relat Res. 1990 Dec;(261):196-213. Clin Orthop Relat Res. 1990. PMID: 2245546
-
Producing and avoiding stress shielding. Laboratory and clinical observations of noncemented total hip arthroplasty.Clin Orthop Relat Res. 1992 Jan;(274):79-96. Clin Orthop Relat Res. 1992. PMID: 1729025
-
Determinants of stress shielding: design versus materials versus interface.Clin Orthop Relat Res. 1992 Jan;(274):202-12. Clin Orthop Relat Res. 1992. PMID: 1729005 Review.
-
Periprosthetic femoral bone loss in total hip arthroplasty: systematic analysis of the effect of stem design.Hip Int. 2017 Feb 21;27(1):26-34. doi: 10.5301/hipint.5000413. Epub 2016 Aug 3. Hip Int. 2017. PMID: 27515762 Review.
Cited by
-
Biomechanical Tests on Long-Bone Elliptical Medullary-Canal Endoprostheses for Limb Salvage in Dogs.Animals (Basel). 2022 Nov 3;12(21):3021. doi: 10.3390/ani12213021. Animals (Basel). 2022. PMID: 36359145 Free PMC article.
-
TiNbSn stems with gradient changes of Young's modulus and stiffness reduce stress shielding compared to the standard fit-and-fill stems.Eur J Med Res. 2023 Jul 3;28(1):214. doi: 10.1186/s40001-023-01199-z. Eur J Med Res. 2023. PMID: 37400903 Free PMC article. Clinical Trial.
-
Changes of bone mineral density after cementless total hip arthroplasty with two different stems.Int Orthop. 2008 Apr;32(2):167-72. doi: 10.1007/s00264-006-0298-1. Epub 2007 Jan 16. Int Orthop. 2008. PMID: 17225187 Free PMC article.
-
Stress Shielding and Bone Resorption of Press-Fit Polyether-Ether-Ketone (PEEK) Hip Prosthesis: A Sawbone Model Study.Polymers (Basel). 2022 Oct 29;14(21):4600. doi: 10.3390/polym14214600. Polymers (Basel). 2022. PMID: 36365594 Free PMC article.
-
PEEK biomaterials in trauma, orthopedic, and spinal implants.Biomaterials. 2007 Nov;28(32):4845-69. doi: 10.1016/j.biomaterials.2007.07.013. Epub 2007 Aug 7. Biomaterials. 2007. PMID: 17686513 Free PMC article. Review.
Publication types
MeSH terms
Substances
Grants and funding
LinkOut - more resources
Full Text Sources
Other Literature Sources