Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Clinical Trial
. 1997 Sep;10(9):2105-9.
doi: 10.1183/09031936.97.10092105.

Flow-dependent effect of formoterol dry-powder inhaled from the Aerolizer

Affiliations
Free article
Clinical Trial

Flow-dependent effect of formoterol dry-powder inhaled from the Aerolizer

K G Nielsen et al. Eur Respir J. 1997 Sep.
Free article

Abstract

The output and size distribution of aerosols from dry powder inhalers are dependent on the flow rate through the device. Therefore, in an in vivo study, we examined the flow-dependency of the effect of formoterol when delivered from a dry powder inhaler, the Aerolizer, in a flow range relevant to schoolchildren. In a preliminary study comprising 126 asthmatic children aged 3-10 yrs, the relationship between age and peak inspiratory flow (PIF) rate through the Aerolizer was determined. Mean PIF was 104 L.min-1 and all children aged > 5 yrs performed a PIF > 60 L.min-1. Sixteen children aged 8-15 yrs with exercise-induced asthma (EIA) took part in the main trial comparing the protective effect of 12 micrograms formoterol inhaled at 60 and 120 L.min-1. The effect from high and low inspiratory flow was judged from the protective effect against EIA 12 h after drug administration. The decrease in forced expiratory volume in one second (FEV1) after exercise was 34% on the placebo day, but only 15% when formoterol was inhaled at the high flow rate. This difference was statistically significant. The decrease in FEV1 was 23% after treatment with formoterol inhaled at the low flow rate, that was not significantly different from placebo or from high-flow formoterol treatment. These clinical findings correspond with the in vitro findings of flow-dependent fine particle mass from the Aerolizer, and corroborate the relationship between fine particle mass of aerosol and clinical effect. The results indicate a flow-dependent effect of formoterol dry powder inhaled from the Aerolizer, within the range of inspiratory flow rate obtainable by school-children. This questions its applicability in children with asthma.

PubMed Disclaimer

Similar articles

Cited by

Publication types

LinkOut - more resources