Automated evaluation of hip axis length for predicting hip fracture
- PMID: 7942153
- DOI: 10.1002/jbmr.5650090714
Automated evaluation of hip axis length for predicting hip fracture
Abstract
The hip axis length has been shown in previous studies to be predictive of hip fracture independent of age and femoral bone density. The first studies of hip axis length were performed by manual measurement of dual x-ray absorptiometry (DXA) scan printouts. In this study, an automated analysis procedure is defined using software tools provided by the DXA manufacturer. Manual and automatic hip axis length measurements in 198 women were highly correlated (r = 0.98). Because of scaling factors of the printout, the automatic measurement was 58% longer than the manual value. Precision of the automatic measurement, based upon triplicate DXA scans of 33 women, was 0.07 cm or 0.68%. To define normative data, the hip axis length was measured from femoral DXA scans of 471 female volunteers aged 40-92 scanned on 14 different Hologic QDR-1000 systems. Mean hip axis length was 10.5 cm, with a standard deviation of 0.62 cm. No significant relationship between hip axis length and age was found (r = 0.07, P = 0.15). Based on previously reported odds ratios corrected for femoral bone density, age, height, and weight, an automatic hip axis length measurement of 11.0 cm is associated with a twofold increase in hip fracture risk compared with a woman with an average hip axis length. A hip axis length value of 11.6 cm increases hip fracture risk by a factor of 4 compared with a woman with a normal hip dimension. We conclude that the hip axis length can be easily incorporated into existing DXA hip analysis software in combination with a bone density measurement.(ABSTRACT TRUNCATED AT 250 WORDS)
Similar articles
-
Simple measurement of femoral geometry predicts hip fracture: the study of osteoporotic fractures.J Bone Miner Res. 1993 Oct;8(10):1211-7. doi: 10.1002/jbmr.5650081008. J Bone Miner Res. 1993. PMID: 8256658
-
Hip axis length measurement using dual-energy X-ray absorptiometry.Rev Rhum Engl Ed. 1997 Apr;64(4):243-8. Rev Rhum Engl Ed. 1997. PMID: 9178396
-
Measurement of femoral geometry in type I and type II osteoporosis: differences in hip axis length consistent with heterogeneity in the pathogenesis of osteoporotic fractures.J Bone Miner Res. 1995 Dec;10(12):1908-12. doi: 10.1002/jbmr.5650101210. J Bone Miner Res. 1995. PMID: 8619371
-
Calcaneus ultrasonometry and dual-energy X-ray absorptiometry for the evaluation of vertebral fracture risk.Calcif Tissue Int. 2006 Oct;79(4):223-9. doi: 10.1007/s00223-005-0098-4. Epub 2006 Sep 14. Calcif Tissue Int. 2006. PMID: 16969597
-
Automatic hip geometric feature extraction in DXA imaging using regional random forest.J Xray Sci Technol. 2019;27(2):207-236. doi: 10.3233/XST-180434. J Xray Sci Technol. 2019. PMID: 30594942 Review.
Cited by
-
Hip geometry and its role in fracture: what do we know so far?Curr Osteoporos Rep. 2003 Jun;1(1):25-31. doi: 10.1007/s11914-003-0005-8. Curr Osteoporos Rep. 2003. PMID: 16036062 Review.
-
The effect of calcium supplementation and Tanner stage on bone density, content and area in teenage women.Osteoporos Int. 1996;6(4):276-83. doi: 10.1007/BF01623385. Osteoporos Int. 1996. PMID: 8883115 Clinical Trial.
-
Basic fibroblast growth factor improves trabecular bone connectivity and bone strength in the lumbar vertebral body of osteopenic rats.Osteoporos Int. 2005 Dec;16(12):1939-47. doi: 10.1007/s00198-005-1969-2. Epub 2005 Aug 5. Osteoporos Int. 2005. PMID: 16086094 Free PMC article.
-
Racial differences in femoral dimensions and their relation to hip fracture.Osteoporos Int. 1996;6(1):22-4. doi: 10.1007/BF01626533. Osteoporos Int. 1996. PMID: 8845595
-
Sex and ethnic differences in bone architecture.Curr Osteoporos Rep. 2004 Jun;2(2):65-9. doi: 10.1007/s11914-004-0006-2. Curr Osteoporos Rep. 2004. PMID: 16036085 Review.
MeSH terms
LinkOut - more resources
Full Text Sources
Medical