Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 1984 Jul;20(1):109-14.
doi: 10.1128/jcm.20.1.109-114.1984.

Rapid detection of herpes simplex virus in clinical specimens by use of a capture biotin-streptavidin enzyme-linked immunosorbent assay

Rapid detection of herpes simplex virus in clinical specimens by use of a capture biotin-streptavidin enzyme-linked immunosorbent assay

L S Nerurkar et al. J Clin Microbiol. 1984 Jul.

Abstract

A sensitive enzyme-linked immunosorbent capture assay with biotin and streptavidin (capture B/SA ELISA) was developed to detect herpes simplex virus (HSV) antigen. Rabbit anti-HSV antibody (immunoglobulin G fraction) was coated on flat-bottom, irradiated, 96-well polystyrene microtiter plates and served to capture HSV antigen. Clinical specimens from patients with genital herpes were added. Biotin-linked rabbit anti-HSV immunoglobulin G was used as the second antibody. The antigen-antibody complex was detected with alkaline phosphatase-conjugated streptavidin, which linked to the biotin. With clinical specimens, the test had a sensitivity of 95.6% and a specificity of 91.4% when compared with the tissue culture method. The presence of HSV antigen in specimens devoid of infectivity was confirmed by blocking the reaction with unlabeled rabbit and human antibody to HSV. The level of antigen detected by the capture B/SA ELISA did not necessarily correlate with the infectivity titer of the specimens. HSV antigens could be detected by the capture B/SA ELISA when the virus infectivity was destroyed at 37 degrees C, by UV irradiation, or by Triton X-100 treatment, but not when hypochlorite treatment was used. Greater sensitivity was obtained when HSV-1- and HSV-2-specific antibody reagents were used simultaneously in each test. The capture B/SA ELISA provides a relatively rapid method (4.5 h) which is quite sensitive and specific when compared with other non-tissue culture, direct assay methods.

PubMed Disclaimer

Similar articles

Cited by

References

    1. J Infect Dis. 1977 Oct;136 Suppl:S304-10 - PubMed
    1. J Clin Microbiol. 1984 May;19(5):631-3 - PubMed
    1. J Clin Microbiol. 1979 Aug;10(2):210-7 - PubMed
    1. J Clin Microbiol. 1979 Nov;10(5):703-7 - PubMed
    1. Methods Biochem Anal. 1980;26:1-45 - PubMed

LinkOut - more resources