Dielectric breakdown of cell membranes
- PMID: 4611517
- PMCID: PMC1334582
- DOI: 10.1016/S0006-3495(74)85956-4
Dielectric breakdown of cell membranes
Abstract
With human and bovine red blood cells and Escherichia coli B, dielectric breakdown of cell membranes could be demonstrated using a Coulter Counter (AEG-Telefunken, Ulm, West Germany) with a hydrodynamic focusing orifice. In making measurements of the size distributions of red blood cells and bacteria versus increasing electric field strength and plotting the pulse heights versus the electric field strength, a sharp bend in the otherwise linear curve is observed due to the dielectric breakdown of the membranes. Solution of Laplace's equation for the electric field generated yields a value of about 1.6 V for the membrane potential at which dielectric breakdown occurs with modal volumes of red blood cells and bacteria. The same value is also calculated for red blood cells by applying the capacitor spring model of Crowley (1973. Biophys. J. 13:711). The corresponding electric field strength generated in the membrane at breakdown is of the order of 4 . 10(6) V/cm and, therefore, comparable with the breakdown voltages for bilayers of most oils. The critical detector voltage for breakdown depends on the volume of the cells. The volume-dependence predicted by Laplace theory with the assumption that the potential generated across the membrane is independent of volume, could be verified experimentally. Due to dielectric breakdown the red blood cells lose hemoglobin completely. This phenomenon was used to study dielectric breakdown of red blood cells in a homogeneous electric field between two flat platinum electrodes. The electric field was applied by discharging a high voltage storage capacitor via a spark gap. The calculated value of the membrane potential generated to produce dielectric breakdown in the homogeneous field is of the same order as found by means of the Coulter Counter. This indicates that mechanical rupture of the red blood cells by the hydrodynamic forces in the orifice of the Coulter Counter could also be excluded as a hemolysing mechanism. The detector voltage (or the electric field strength in the orifice) depends on the membrane composition (or the intrinsic membrane potential) as revealed by measuring the critical voltage in E. coli B harvested from the logarithmic and stationary growth phases. The critical detector voltage increased by about 30% for a given volume on reaching the stationary growth phase.
Similar articles
-
Preparation of erythrocyte ghosts by dielectric breakdown of the cell membrane.Biochim Biophys Acta. 1975 Jan 28;375(2):209-19. doi: 10.1016/0005-2736(75)90189-3. Biochim Biophys Acta. 1975. PMID: 1168495
-
Release and uptake of haemoglobin and ions in red blood cells induced by dielectric breakdown.Biochim Biophys Acta. 1975 Jul 3;394(3):449-62. doi: 10.1016/0005-2736(75)90296-5. Biochim Biophys Acta. 1975. PMID: 1131371
-
Transcellular ion flow in Escherichia coli B and electrical sizing of bacterias.Biophys J. 1973 Oct;13(10):1005-13. doi: 10.1016/S0006-3495(73)86041-2. Biophys J. 1973. PMID: 4583964 Free PMC article.
-
Electroporation theory. Concepts and mechanisms.Methods Mol Biol. 1995;47:1-26. doi: 10.1385/0-89603-310-4:1. Methods Mol Biol. 1995. PMID: 7550723 Review.
-
Electroporation theory. Concepts and mechanisms.Methods Mol Biol. 1995;55:3-28. doi: 10.1385/0-89603-328-7:3. Methods Mol Biol. 1995. PMID: 8528421 Review.
Cited by
-
Gene Electrotransfer: A Mechanistic Perspective.Curr Gene Ther. 2016;16(2):98-129. doi: 10.2174/1566523216666160331130040. Curr Gene Ther. 2016. PMID: 27029943 Free PMC article. Review.
-
Kinetics of permeability changes induced by electric impulses in chromaffin granules.J Membr Biol. 1977 Apr 22;32(3-4):231-54. doi: 10.1007/BF01905221. J Membr Biol. 1977. PMID: 864679
-
Erythrocyte and ghost cytoplasmic resistivity and voltage-dependent apparent size.Biophys J. 1983 Dec;44(3):397-403. doi: 10.1016/S0006-3495(83)84313-6. Biophys J. 1983. PMID: 6661495 Free PMC article.
-
Selective Release of Recombinant Periplasmic Protein From E. coli Using Continuous Pulsed Electric Field Treatment.Front Bioeng Biotechnol. 2021 Feb 9;8:586833. doi: 10.3389/fbioe.2020.586833. eCollection 2020. Front Bioeng Biotechnol. 2021. PMID: 33634078 Free PMC article.
-
Nanoelectronics-biology frontier: From nanoscopic probes for action potential recording in live cells to three-dimensional cyborg tissues.Nano Today. 2013 Aug 1;8(4):351-373. doi: 10.1016/j.nantod.2013.05.001. Nano Today. 2013. PMID: 24073014 Free PMC article.
References
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Miscellaneous