A canine composite femoral stem. An in vivo study
- PMID: 3416529
A canine composite femoral stem. An in vivo study
Abstract
To evaluate a carbon fiber/polysulfone composite femoral stem, a press-fit unilateral hemiarthroplasty was performed in 17 greyhounds. The implant was designed to have strength and elastic properties commensurate with the proximal canine femur. The implant geometry was such that the naturally occurring internal cancellous structures of the proximal femur would be preserved and participate in load transfer from the implant to the bone. Animals were killed at one, five, ten, 16, and 24 months. At necropsy all the femoral stems were well fixed and functioning. All implants maintained their structural integrity. Radiographs and computed tomography scans showed a constructive bone remodeling response. Histologic analysis revealed a benign host tissue response, with few inflammatory cells observed. Both bone and fibrous tissue were observed at the implant-host tissue interface. Implants fabricated from carbon/polysulfone composites have the potential for use in load-bearing applications. An implant with appropriate elastic properties provides the opportunity for the natural bone remodeling response to enhance implant stability. Naturally occurring internal cancellous structures can be utilized for load transfer by femoral components. Press-fit devices with no physical or chemical bone-bonding mechanisms can attain long-term successful functional performance.
Similar articles
-
Porous polysulfone coatings for fixation of femoral stems by bony ingrowth.Clin Orthop Relat Res. 1983 Jun;(176):34-41. Clin Orthop Relat Res. 1983. PMID: 6851340
-
Porous polymers for biological fixation.Clin Orthop Relat Res. 1988 Oct;(235):207-19. Clin Orthop Relat Res. 1988. PMID: 2970907
-
Porous-coated femoral components in a canine model for revision arthroplasty.J Bone Joint Surg Am. 1988 Sep;70(8):1201-8. J Bone Joint Surg Am. 1988. PMID: 3417705
-
Effect of surgical technique and use of a rigid centralizing device on stem positioning and geometric reconstruction in the sagittal plane during total hip replacement in canine cadavers.Am J Vet Res. 1999 Sep;60(9):1126-35. Am J Vet Res. 1999. PMID: 10490084
-
Metal-carbon fiber composite femoral stems in hip replacements: a randomized controlled parallel-group study with mean ten-year follow-up.J Bone Joint Surg Am. 2014 Dec 17;96(24):2062-9. doi: 10.2106/JBJS.M.01542. J Bone Joint Surg Am. 2014. PMID: 25520340 Clinical Trial.
Cited by
-
PEEK biomaterials in trauma, orthopedic, and spinal implants.Biomaterials. 2007 Nov;28(32):4845-69. doi: 10.1016/j.biomaterials.2007.07.013. Epub 2007 Aug 7. Biomaterials. 2007. PMID: 17686513 Free PMC article. Review.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources