Cavitation threshold measurements for microsecond length pulses of ultrasound
- PMID: 3411016
- DOI: 10.1121/1.396347
Cavitation threshold measurements for microsecond length pulses of ultrasound
Abstract
The acoustic cavitation threshold of an aqueous solution has been measured at megahertz frequencies as a function of pulse width and pulse repetition frequency for various combinations of these quantities. The fluid tested was a 0.1M KOH-H3BO3 buffer solution with pH 10.9, which contained luminol, was saturated with argon, and filtered to 25 mu. The presence of cavitation was detected by a photomultiplier tube that required the emission of visible light that was both larger in magnitude and longer in duration than a preset criterion. It was observed that the cavitation threshold of water under pulse conditions decreases both when the pulse width is fixed and the pulse repetition frequency is increased, and when the pulse repetition frequency is fixed and the pulse width is increased. Acoustic cavitation thresholds measured in aqueous solutions are significantly less than those acoustic pressures associated with instruments that are currently in widespread use in medicine.
Similar articles
-
Thresholds for cavitation produced in water by pulsed ultrasound.Ultrasonics. 1988 Sep;26(5):280-5. doi: 10.1016/0041-624x(88)90018-2. Ultrasonics. 1988. PMID: 3407017
-
An acoustic backscattering technique for the detection of transient cavitation produced by microsecond pulses of ultrasound.J Acoust Soc Am. 1990 Jun;87(6):2451-8. doi: 10.1121/1.399091. J Acoust Soc Am. 1990. PMID: 2373791
-
Exploiting flow to control the in vitro spatiotemporal distribution of microbubble-seeded acoustic cavitation activity in ultrasound therapy.Phys Med Biol. 2014 Nov 21;59(22):6941-57. doi: 10.1088/0031-9155/59/22/6941. Epub 2014 Oct 28. Phys Med Biol. 2014. PMID: 25350470
-
Acoustic cavitation produced by microsecond pulses of ultrasound: a discussion of some selected results.J Acoust Soc Am. 1992 Feb;91(2):1113-9. doi: 10.1121/1.402638. J Acoust Soc Am. 1992. PMID: 1556312 Review.
-
Effects of pulsed ultrasound on the mouse neonate: hind limb paralysis and lung hemorrhage.Ultrasound Med Biol. 1994;20(1):53-63. doi: 10.1016/0301-5629(94)90017-5. Ultrasound Med Biol. 1994. PMID: 8197627 Review.
Cited by
-
Characteristics of the secondary bubble cluster produced by an electrohydraulic shock wave lithotripter.Ultrasound Med Biol. 2012 Apr;38(4):601-10. doi: 10.1016/j.ultrasmedbio.2011.12.022. Ultrasound Med Biol. 2012. PMID: 22390990 Free PMC article.
-
Effects of ultrasound frequency and tissue stiffness on the histotripsy intrinsic threshold for cavitation.Ultrasound Med Biol. 2015 Jun;41(6):1651-67. doi: 10.1016/j.ultrasmedbio.2015.01.028. Epub 2015 Mar 9. Ultrasound Med Biol. 2015. PMID: 25766571 Free PMC article.
-
Lesion generation through ribs using histotripsy therapy without aberration correction.IEEE Trans Ultrason Ferroelectr Freq Control. 2011 Nov;58(11):2334-43. doi: 10.1109/TUFFC.2011.2091. IEEE Trans Ultrason Ferroelectr Freq Control. 2011. PMID: 22083767 Free PMC article.
-
An efficient treatment strategy for histotripsy by removing cavitation memory.Ultrasound Med Biol. 2012 May;38(5):753-66. doi: 10.1016/j.ultrasmedbio.2012.01.013. Epub 2012 Mar 6. Ultrasound Med Biol. 2012. PMID: 22402025 Free PMC article.
-
Controlled ultrasound tissue erosion.IEEE Trans Ultrason Ferroelectr Freq Control. 2004 Jun;51(6):726-36. doi: 10.1109/tuffc.2004.1308731. IEEE Trans Ultrason Ferroelectr Freq Control. 2004. PMID: 15244286 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Research Materials