A theoretical analysis of interrupter technique for measuring respiratory mechanics
- PMID: 3391919
- DOI: 10.1152/jappl.1988.64.5.2204
A theoretical analysis of interrupter technique for measuring respiratory mechanics
Abstract
The application of the flow interrupter technique to series and parallel models of the respiratory system is examined theoretically, assuming instantaneous transmission of pressures and incompressible gases in the lung air spaces. The initial pressure change observed immediately after occlusion divided by the preocclusion flow gives an initial resistance (Rinit) equal to that of the airway tree when the model consists of compartments connected in parallel. When the compartments are connected in series, Rinit is the resistance of the most proximal airway only. In general, the initial pressure change is followed by a second slower change, reflecting equilibration of pressures between the compartments. The total postocclusion pressure change divided by the flow gives a steady-state resistance (Rss) whose value depends on the ventilation history before occlusion. When this history consists of a relaxed expiration Rss asymptotes from Rinit to a value higher than the zero-frequency resistance of the model as the expiratory time increases. However, the relative contributions of serial and parallel pendelluft and viscoelasticity to Rss cannot be determined from pressure and flow measurements made at the airway opening. Therefore in disease, the interrupter method does not permit one to say whether ventilation inhomogeneity or alteration in lung tissue properties is the predominant abnormality.
Similar articles
-
Analysis of the behavior of the respiratory system with constant inspiratory flow.J Appl Physiol (1985). 1985 Jun;58(6):1840-8. doi: 10.1152/jappl.1985.58.6.1840. J Appl Physiol (1985). 1985. PMID: 4008404
-
Respiratory mechanics determined by flow interruption during passive expiration in cats.Respir Physiol. 1989 Nov;78(2):243-52. doi: 10.1016/0034-5687(89)90056-x. Respir Physiol. 1989. PMID: 2609031
-
A comparison of interrupter and forced oscillation measurements of respiratory resistance in the dog.J Appl Physiol (1985). 1992 Jan;72(1):46-52. doi: 10.1152/jappl.1992.72.1.46. J Appl Physiol (1985). 1992. PMID: 1537743
-
Two-compartment modelling of respiratory system mechanics at low frequencies: gas redistribution or tissue rheology?Eur Respir J. 1991 Mar;4(3):353-8. Eur Respir J. 1991. PMID: 1864351 Review.
-
What does airway resistance tell us about lung function?Respir Care. 2012 Jan;57(1):85-96; discussion 96-9. doi: 10.4187/respcare.01411. Respir Care. 2012. PMID: 22222128 Review.
Cited by
-
Respiratory mechanical properties during fentanyl and alfentanil anaesthesia.Can J Anaesth. 1992 May;39(5 Pt 1):458-65. doi: 10.1007/BF03008710. Can J Anaesth. 1992. PMID: 1596970
-
Respiratory Mechanics and Diaphragmatic Dysfunction in COPD Patients Who Failed Non-Invasive Mechanical Ventilation.Int J Chron Obstruct Pulmon Dis. 2019 Nov 22;14:2575-2585. doi: 10.2147/COPD.S219125. eCollection 2019. Int J Chron Obstruct Pulmon Dis. 2019. PMID: 31819395 Free PMC article.
-
Use of interrupter technique in assessment of bronchial responsiveness in normal subjects.BMC Pulm Med. 2004 Nov 12;4:11. doi: 10.1186/1471-2466-4-11. BMC Pulm Med. 2004. PMID: 15541173 Free PMC article.
-
Measuring time-varying respiratory mechanics during anesthesia.J Anesth. 1995 Jun;9(2):151-157. doi: 10.1007/BF02479847. J Anesth. 1995. PMID: 28921284
-
Pattern of lung emptying and expiratory resistance in mechanically ventilated patients with chronic obstructive pulmonary disease.Intensive Care Med. 2004 Jul;30(7):1311-8. doi: 10.1007/s00134-004-2255-z. Epub 2004 Mar 31. Intensive Care Med. 2004. PMID: 15054570 Clinical Trial.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources