Estimation of optical pathlength through tissue from direct time of flight measurement
- PMID: 3237772
- DOI: 10.1088/0031-9155/33/12/008
Estimation of optical pathlength through tissue from direct time of flight measurement
Abstract
Quantitation of near infrared spectroscopic data in a scattering medium such as tissue requires knowledge of the optical pathlength in the medium. This can now be estimated directly from the time of flight of picosecond length light pulses. Monte Carlo modelling of light pulses in tissue has shown that the mean value of the time dispersed light pulse correlates with the pathlength used in quantitative spectroscopic calculations. This result has been verified in a phantom material. Time of flight measurements of pathlength across the rat head give a pathlength of 5.3 +/- 0.3 times the head diameter.
Similar articles
-
Quantitative analysis of the hemoglobin oxygenation state of rat brain in vivo by picosecond time-resolved spectrophotometry.J Biochem. 1991 Mar;109(3):455-61. doi: 10.1093/oxfordjournals.jbchem.a123403. J Biochem. 1991. PMID: 1880133
-
A Monte Carlo investigation of optical pathlength in inhomogeneous tissue and its application to near-infrared spectroscopy.Phys Med Biol. 1993 Dec;38(12):1859-76. doi: 10.1088/0031-9155/38/12/011. Phys Med Biol. 1993. PMID: 8108489
-
Differential pathlength factor estimation for brain-like tissue from a single-layer Monte Carlo model.Annu Int Conf IEEE Eng Med Biol Soc. 2015;2015:3279-82. doi: 10.1109/EMBC.2015.7319092. Annu Int Conf IEEE Eng Med Biol Soc. 2015. PMID: 26736992
-
Pathlength determination for gas in scattering media absorption spectroscopy.Sensors (Basel). 2014 Feb 25;14(3):3871-90. doi: 10.3390/s140303871. Sensors (Basel). 2014. PMID: 24573311 Free PMC article. Review.
-
[Mammography with light--possibilities and limits].Aktuelle Radiol. 1995 Mar;5(2):115-9. Aktuelle Radiol. 1995. PMID: 7756362 Review. German.
Cited by
-
Cerebral haemodynamics during simulated driving: Changes in workload are detectable with functional near infrared spectroscopy.PLoS One. 2021 Mar 12;16(3):e0248533. doi: 10.1371/journal.pone.0248533. eCollection 2021. PLoS One. 2021. PMID: 33711078 Free PMC article. Clinical Trial.
-
Prefrontal Functional Connectivity During the Verbal Fluency Task in Patients With Major Depressive Disorder: A Functional Near-Infrared Spectroscopy Study.Front Psychiatry. 2021 May 21;12:659814. doi: 10.3389/fpsyt.2021.659814. eCollection 2021. Front Psychiatry. 2021. PMID: 34093276 Free PMC article.
-
Sex based differences in functional connectivity during a working memory task: an fNIRS study.Front Psychol. 2024 Feb 8;15:1207202. doi: 10.3389/fpsyg.2024.1207202. eCollection 2024. Front Psychol. 2024. PMID: 38390414 Free PMC article.
-
Local and remote thermoregulatory changes affect NIRS measurement in forearm muscles.Eur J Appl Physiol. 2015 Nov;115(11):2281-91. doi: 10.1007/s00421-015-3208-7. Epub 2015 Jul 4. Eur J Appl Physiol. 2015. PMID: 26142276
-
The Various Oximetric Techniques Used for the Evaluation of Blood Oxygenation.Sensors (Basel). 2020 Aug 27;20(17):4844. doi: 10.3390/s20174844. Sensors (Basel). 2020. PMID: 32867184 Free PMC article. Review.
Publication types
MeSH terms
Grants and funding
LinkOut - more resources
Full Text Sources
Other Literature Sources