Dimensional stability of double-processed complete denture bases fabricated with compression molding, injection molding, and CAD-CAM subtraction milling
- PMID: 31761276
- DOI: 10.1016/j.prosdent.2019.09.011
Dimensional stability of double-processed complete denture bases fabricated with compression molding, injection molding, and CAD-CAM subtraction milling
Abstract
Statement of problem: Studies evaluating the dimensional stability of denture bases fabricated by the double processing method are lacking.
Purpose: The purpose of this in vitro study was to evaluate the dimensional stability of denture bases fabricated by 3 different techniques: compression molding, injection molding, and computer-aided design and computer-aided manufacturing (CAD-CAM) subtraction milling.
Material and methods: Forty-five mandibular denture bases were fabricated from a master cast by a standardized process. A double processing protocol was used with 3 methods: compression molding (PRESS), injection molding (INJECT), or CAD-CAM (CAD). The bases were compared with the titanium master cast after the first processing. By a digital subtraction process, the dimensional stability of the bases was measured at 22 different locations on the intaglio surface. Denture teeth were then positioned according to a standardized protocol, and the denture was processed a second time and finished. The dimensional discrepancy was reassessed after the second processing and compared with the titanium master cast.
Results: In all groups, most of the dimensional changes occurred during the first processing (P<.05), with no statistically significant deformation occurring during the second processing (P>.05). The CAD group presented significantly smaller dimensional changes than PRESS (P<.05) and INJECT (P<.05) groups. No significant difference was found in the dimensional stability in the PRESS and INJECT groups (P>.05).
Conclusions: Denture bases fabricated by a CAD-CAM methodology exhibit fewer dimensional changes than either compression or injection molding. Distortion occurred during the fabrication of the denture base, and a second processing did not significantly affect the dimensional stability of the denture base.
Copyright © 2019 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
Similar articles
-
Comparison of Fit of Dentures Fabricated by Traditional Techniques Versus CAD/CAM Technology.J Prosthodont. 2019 Apr;28(4):428-435. doi: 10.1111/jopr.12604. Epub 2017 Nov 14. J Prosthodont. 2019. PMID: 29136309
-
Evaluation of the trueness and tissue surface adaptation of CAD-CAM mandibular denture bases manufactured using digital light processing.J Prosthet Dent. 2018 Dec;120(6):919-926. doi: 10.1016/j.prosdent.2018.01.027. Epub 2018 Jun 28. J Prosthet Dent. 2018. PMID: 29961610
-
Comparison of Dimensional Changes Between CAD-CAM Milled Complete Denture Bases and 3D Printed Complete Denture Bases: An In Vitro Study.J Prosthodont. 2023 Apr;32(S1):11-19. doi: 10.1111/jopr.13538. Epub 2022 May 18. J Prosthodont. 2023. PMID: 35524633
-
Accuracy of digital complete dentures: A systematic review of in vitro studies.J Prosthet Dent. 2021 Feb;125(2):249-256. doi: 10.1016/j.prosdent.2020.01.004. Epub 2020 Feb 27. J Prosthet Dent. 2021. PMID: 32115218 Review.
-
Additive Manufacturing for Complete Denture Fabrication: A Narrative Review.J Prosthodont. 2022 Mar;31(S1):47-51. doi: 10.1111/jopr.13426. J Prosthodont. 2022. PMID: 35313025 Review.
Cited by
-
Evaluation of the effect of thermocycling on the trueness and precision of digitally fabricated complete denture bases.BMC Oral Health. 2024 Aug 23;24(1):983. doi: 10.1186/s12903-024-04636-5. BMC Oral Health. 2024. PMID: 39180008 Free PMC article.
-
Effect of Duplication Techniques on the Fitting Accuracy of CAD-CAM Milled, 3D-Printed, and Injection-Molded Mandibular Complete Denture Bases.Dent J (Basel). 2024 Feb 2;12(2):32. doi: 10.3390/dj12020032. Dent J (Basel). 2024. PMID: 38392236 Free PMC article.
-
The accuracy and retention of presurgical infant orthopaedics constructed from different polymer materials: A comparative study.J Taibah Univ Med Sci. 2024 Feb 5;19(2):379-389. doi: 10.1016/j.jtumed.2024.01.005. eCollection 2024 Apr. J Taibah Univ Med Sci. 2024. PMID: 38370166 Free PMC article.
-
Ranking Technologies of Additive Manufacturing of Removable Complete Dentures by the Results of Their Mechanical Testing.Dent J (Basel). 2023 Nov 13;11(11):265. doi: 10.3390/dj11110265. Dent J (Basel). 2023. PMID: 37999029 Free PMC article.
-
Comparative Evaluation of the Digital Workflow and Conventional Method in Manufacturing Complete Removal Prostheses.Materials (Basel). 2023 Oct 30;16(21):6955. doi: 10.3390/ma16216955. Materials (Basel). 2023. PMID: 37959552 Free PMC article. Review.
MeSH terms
LinkOut - more resources
Full Text Sources
Research Materials
Miscellaneous