Accuracy of digitally fabricated trial dentures
- PMID: 28969915
- DOI: 10.1016/j.prosdent.2017.06.020
Accuracy of digitally fabricated trial dentures
Abstract
Statement of problem: Information about the accuracy of digital computer-aided design and computer-aided manufacturing (CAD-CAM) complete dentures is scarce.
Purpose: The purpose of this in vitro study was to assess the reproducibility of the occlusion of wax dentures fabricated with digital steps and the contraction behavior of wax trial dentures processed with combined conventional-digital steps. These were compared with those fabricated completely conventionally in terms of storage duration.
Material and methods: Five sets of maxillary and mandibular wax trial dentures were milled from a gingiva-colored wax blank (Ceramill D-Wax, Amann Girrbach AG) using the Ceramill Motion 2 System (Amann Girrbach), scanned, and matched by best-fit triangulation for each of the 5 denture pairs. Processing deformation was measured and the maximum deviations calculated. A 3-dimensional color-coded mapping of the differences between each pair of dentures was generated. Five sets of maxillary and mandibular wax trial dentures were processed with digital steps, and 5 sets of maxillary and mandibular wax trial dentures were fabricated in the conventional way with the help of a silicone index from a CAM-fabricated wax trial denture to standardize the wax amount. All dentures were scanned immediately after waxing and after 1 week of storage. After surface matching, the deformation was measured, and the milled wax bases were compared with those conventionally fabricated. Data were interpreted using descriptive statistics.
Results: The occlusion of wax trial dentures fabricated with digital steps was not reproducible. The deviations in the maxillary dentures were mostly marginal, with exceptions for single teeth/tooth groups in denture No. 2 (occlusal areas of teeth in second quadrant, second molars) and No. 4 (central incisor and canine in second quadrant inclined to palatal side, and first premolar in first quadrant and first molar in second quadrant displayed greater deviations). Among the mandibular dentures, denture Nos. 4 and 5 the central incisor (fourth quadrant) inclined to the labial side. Additionally, in denture No. 5 the lateral incisor (fourth quadrant) inclined to the lingual side.
Conclusions: In digitally fabricated dentures, the manual placing of the teeth into the denture base sockets can lead to deviations from the planned arrangement. The deviations were greater in the area of the denture bases in the conventionally fabricated dentures compared with those processed with combined conventional-digital steps. The milled wax bases showed better contraction behavior than the conventionally fabricated wax bases.
Copyright © 2018 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
Similar articles
-
Accuracy of Digitally Fabricated Wax Denture Bases and Conventional Completed Complete Dentures.Dent J (Basel). 2017 Dec 19;5(4):36. doi: 10.3390/dj5040036. Dent J (Basel). 2017. PMID: 29563442 Free PMC article.
-
Dimensional changes of complete dentures fabricated by milled and printed techniques: An in vitro study.J Prosthet Dent. 2023 Apr;129(4):608-615. doi: 10.1016/j.prosdent.2021.06.042. Epub 2021 Aug 5. J Prosthet Dent. 2023. PMID: 34364688
-
Trueness and precision of artificial teeth in CAD-CAM milled complete dentures with custom disks.J Prosthet Dent. 2022 Oct;128(4):695-701. doi: 10.1016/j.prosdent.2020.12.049. Epub 2021 Mar 26. J Prosthet Dent. 2022. PMID: 33773771
-
Accuracy of digital complete dentures: A systematic review of in vitro studies.J Prosthet Dent. 2021 Feb;125(2):249-256. doi: 10.1016/j.prosdent.2020.01.004. Epub 2020 Feb 27. J Prosthet Dent. 2021. PMID: 32115218 Review.
-
Additive Manufacturing for Complete Denture Fabrication: A Narrative Review.J Prosthodont. 2022 Mar;31(S1):47-51. doi: 10.1111/jopr.13426. J Prosthodont. 2022. PMID: 35313025 Review.
Cited by
-
Repair Bond Strength of Conventionally and Digitally Fabricated Denture Base Resins to Auto-Polymerized Acrylic Resin: Surface Treatment Effects In Vitro.Materials (Basel). 2022 Dec 19;15(24):9062. doi: 10.3390/ma15249062. Materials (Basel). 2022. PMID: 36556867 Free PMC article.
-
Comparison of cooling methods on denture base adaptation of rapid heat-cured acrylic using a three-dimensional superimposition technique.J Indian Prosthodont Soc. 2021 Apr-Jun;21(2):198-203. doi: 10.4103/jips.jips_41_21. J Indian Prosthodont Soc. 2021. PMID: 33938871 Free PMC article.
-
Clinical application and research progress of digital complete denture.Hua Xi Kou Qiang Yi Xue Za Zhi. 2021 Feb 1;39(1):1-8. doi: 10.7518/hxkq.2021.01.001. Hua Xi Kou Qiang Yi Xue Za Zhi. 2021. PMID: 33723930 Free PMC article. Review. Chinese, English.
-
Accuracy of CAD/CAM-fabricated bite splints: milling vs 3D printing.Clin Oral Investig. 2020 Dec;24(12):4607-4615. doi: 10.1007/s00784-020-03329-x. Epub 2020 May 21. Clin Oral Investig. 2020. PMID: 32436163 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Research Materials
Miscellaneous