Rapid electrochemical detection on a mobile phone
- PMID: 23689554
- DOI: 10.1039/c3lc50306b
Rapid electrochemical detection on a mobile phone
Abstract
We present a compact mobile phone platform for rapid, quantitative biomolecular detection. This system consists of an embedded circuit for signal processing and data analysis, and disposable microfluidic chips for fluidic handling and biosensing. Capillary flow is employed for sample loading, processing, and pumping to enhance operational portability and simplicity. Graphical step-by-step instructions displayed on the phone assists the operator through the detection process. After the completion of each measurement, the results are displayed on the screen for immediate assessment and the data is automatically saved to the phone's memory for future analysis and transmission. Validation of this device was carried out by detecting Plasmodium falciparum histidine-rich protein 2 (PfHRP2), an important biomarker for malaria, with a lower limit of detection of 16 ng mL(-1) in human serum. The simple detection process can be carried out with two loading steps and takes 15 min to complete each measurement. Due to its compact size and high performance, this device offers immense potential as a widely accessible, point-of-care diagnostic platform, especially in remote and rural areas. In addition to its impact on global healthcare, this technology is relevant to other important applications including food safety, environmental monitoring and biosecurity.
Similar articles
-
Magneto immunoassays for Plasmodium falciparum histidine-rich protein 2 related to malaria based on magnetic nanoparticles.Anal Chem. 2011 Jul 15;83(14):5570-7. doi: 10.1021/ac200573s. Epub 2011 Jun 24. Anal Chem. 2011. PMID: 21619038
-
Progress toward multiplexed sample-to-result detection in low resource settings using microfluidic immunoassay cards.Lab Chip. 2012 Mar 21;12(6):1119-27. doi: 10.1039/c2lc20751f. Epub 2012 Feb 7. Lab Chip. 2012. PMID: 22311085
-
Trial with ParaSight-F in the detection of Plasmodium falciparum infection in Chennai (Tamil Nadu), India.Indian J Malariol. 1998 Sep;35(3):160-2. Indian J Malariol. 1998. PMID: 10497842
-
Paper-based microfluidic point-of-care diagnostic devices.Lab Chip. 2013 Jun 21;13(12):2210-51. doi: 10.1039/c3lc50169h. Epub 2013 May 8. Lab Chip. 2013. PMID: 23652632 Review.
-
Smartphones for cell and biomolecular detection.Ann Biomed Eng. 2014 Nov;42(11):2205-17. doi: 10.1007/s10439-014-1055-z. Epub 2014 Jun 11. Ann Biomed Eng. 2014. PMID: 24916841 Review.
Cited by
-
Smartphone-driven centrifugal microfluidics for diagnostics in resource limited settings.Biomed Microdevices. 2024 Oct 26;26(4):43. doi: 10.1007/s10544-024-00726-x. Biomed Microdevices. 2024. PMID: 39460830 Free PMC article.
-
C-MEMS-derived glassy carbon electrochemical biosensors for rapid detection of SARS-CoV-2 spike protein.Microsyst Nanoeng. 2023 Nov 6;9:137. doi: 10.1038/s41378-023-00601-4. eCollection 2023. Microsyst Nanoeng. 2023. PMID: 37937185 Free PMC article.
-
A free customizable tool for easy integration of microfluidics and smartphones.Sci Rep. 2022 May 27;12(1):8969. doi: 10.1038/s41598-022-13099-z. Sci Rep. 2022. PMID: 35624294 Free PMC article.
-
Human-Device Interaction in the Life Science Laboratory.Adv Biochem Eng Biotechnol. 2022;182:83-113. doi: 10.1007/10_2021_183. Adv Biochem Eng Biotechnol. 2022. PMID: 35091814
-
Recent Advancements in the Technologies Detecting Food Spoiling Agents.J Funct Biomater. 2021 Nov 27;12(4):67. doi: 10.3390/jfb12040067. J Funct Biomater. 2021. PMID: 34940546 Free PMC article. Review.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources