Virtual elastic sphere processing enables reproducible quantification of vessel stenosis at CT and MR angiography
- PMID: 21788527
- DOI: 10.1148/radiol.11110069
Virtual elastic sphere processing enables reproducible quantification of vessel stenosis at CT and MR angiography
Abstract
Purpose: To develop and evaluate a user-friendly tool to enable efficient, accurate, and reproducible quantification of blood vessel stenosis in computed tomographic (CT) and magnetic resonance (MR) angiographic data sets.
Materials and methods: All clinical experiments were approved by the institutional review board, and informed patient consent was acquired. Animal experiments were approved by the governmental review committee on animal care. A virtual elastic sphere passes through a blood vessel specified by user-provided start and end points, and the adapting diameter over the course of the vessel is recorded. The program was tested in phantoms to determine the accuracy of diameter estimation, and it was applied in micro-CT data sets of mice with induced vessel stenosis. Dual-energy CT angiography and MR angiography were performed in 16 patients with carotid artery stenosis, and reproducibility and required reader time of this automated technique were compared with manual measurements. Additionally, the effect of dual-energy CT-based discrimination between iodine- and calcium-based enhancement was investigated. Differences between carotid artery diameters of mice and between automated and manual measurement durations were assessed with a paired t test. Reproducibility of stenosis scores was evaluated with the Fisher z test.
Results: Phantom diameters were determined with an average error of 0.094 mm. Diameters of normal and injured carotid arteries of mice were significantly different (P < .01). For patient data, automated interreader variability was significantly (P < .01) lower than manual intra- and interreader variability, while time efficiency was improved (P < .01).
Conclusion: The virtual elastic sphere tool is applicable to CT, dual-energy CT, and MR angiography, and it improves reproducibility and efficiency over that achieved with manual stenosis measurements.
Similar articles
-
Supraaortic arteries: contrast-enhanced MR angiography at 3.0 T--highly accelerated parallel acquisition for improved spatial resolution over an extended field of view.Radiology. 2007 Feb;242(2):600-9. doi: 10.1148/radiol.2422051784. Radiology. 2007. PMID: 17255428
-
High-spatial-resolution MR angiography of renal arteries with integrated parallel acquisitions: comparison with digital subtraction angiography and US.Radiology. 2005 May;235(2):687-98. doi: 10.1148/radiol.2352031693. Epub 2005 Mar 15. Radiology. 2005. PMID: 15770035
-
Relationship between coronary artery disease and epicardial adipose tissue quantification at cardiac CT: comparison between automatic volumetric measurement and manual bidimensional estimation.Acad Radiol. 2010 Jun;17(6):727-34. doi: 10.1016/j.acra.2010.01.015. Epub 2010 Apr 3. Acad Radiol. 2010. PMID: 20363161
-
Coronary CT versus MR angiography: pro CT--the role of CT angiography.Radiology. 2011 Feb;258(2):329-39. doi: 10.1148/radiol.10100161. Radiology. 2011. PMID: 21273517 Review. No abstract available.
-
Postprocessing techniques for cardiac computed tomographic angiography.Radiol Clin North Am. 2010 Jul;48(4):687-700. doi: 10.1016/j.rcl.2010.04.004. Epub 2010 Jun 11. Radiol Clin North Am. 2010. PMID: 20705166 Review.
Cited by
-
Quantification of Hepatic Vascular and Parenchymal Regeneration in Mice.PLoS One. 2016 Aug 5;11(8):e0160581. doi: 10.1371/journal.pone.0160581. eCollection 2016. PLoS One. 2016. PMID: 27494255 Free PMC article.
-
Performance of lead-free versus lead-based hunting ammunition in ballistic soap.PLoS One. 2014 Jul 16;9(7):e102015. doi: 10.1371/journal.pone.0102015. eCollection 2014. PLoS One. 2014. PMID: 25029572 Free PMC article.
-
MicroRNA-155 promotes atherosclerosis by repressing Bcl6 in macrophages.J Clin Invest. 2012 Nov;122(11):4190-202. doi: 10.1172/JCI61716. Epub 2012 Oct 8. J Clin Invest. 2012. PMID: 23041630 Free PMC article.
-
MicroRNA-126-5p promotes endothelial proliferation and limits atherosclerosis by suppressing Dlk1.Nat Med. 2014 Apr;20(4):368-76. doi: 10.1038/nm.3487. Epub 2014 Mar 2. Nat Med. 2014. PMID: 24584117 Free PMC article.
-
Absorption reconstruction improves biodistribution assessment of fluorescent nanoprobes using hybrid fluorescence-mediated tomography.Theranostics. 2014 Jul 26;4(10):960-71. doi: 10.7150/thno.9293. eCollection 2014. Theranostics. 2014. PMID: 25157277 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical