The B-matrix must be rotated when correcting for subject motion in DTI data
- PMID: 19319973
- DOI: 10.1002/mrm.21890
The B-matrix must be rotated when correcting for subject motion in DTI data
Abstract
To estimate diffusion tensor MRI (DTI) measures, such as fractional anisotropy and fiber orientation, reliably, a large number of diffusion-encoded images is needed, preferably cardiac gated to reduce pulsation artifacts. However, the concomitant longer acquisition times increase the chances of subject motion adversely affecting the estimation of these measures. While correcting for motion artifacts improves the accuracy of DTI, an often overlooked step in realigning the images is to reorient the B-matrix so that orientational information is correctly preserved. To the best of our knowledge, most research groups and software packages currently omit this reorientation step. Given the recent explosion of DTI applications including, for example, neurosurgical planning (in which errors can have drastic consequences), it is important to investigate the impact of neglecting to perform the B-matrix reorientation. In this work, a systematic study to investigate the effect of neglecting to reorient the B-matrix on DTI data during motion correction is presented. The consequences for diffusion fiber tractography are also discussed.
Similar articles
-
On the effects of dephasing due to local gradients in diffusion tensor imaging experiments: relevance for diffusion tensor imaging fiber phantoms.Magn Reson Imaging. 2009 May;27(4):541-8. doi: 10.1016/j.mri.2008.08.011. Epub 2008 Oct 31. Magn Reson Imaging. 2009. PMID: 18977104
-
Motion correction and registration of high b-value diffusion weighted images.Magn Reson Med. 2012 Jun;67(6):1694-702. doi: 10.1002/mrm.23186. Epub 2011 Dec 19. Magn Reson Med. 2012. PMID: 22183784
-
Automated artifact detection and removal for improved tensor estimation in motion-corrupted DTI data sets using the combination of local binary patterns and 2D partial least squares.Magn Reson Imaging. 2011 Feb;29(2):230-42. doi: 10.1016/j.mri.2010.06.022. Epub 2010 Dec 3. Magn Reson Imaging. 2011. PMID: 21129881
-
Diffusion tensor MR imaging and fiber tractography: technical considerations.AJNR Am J Neuroradiol. 2008 May;29(5):843-52. doi: 10.3174/ajnr.A1052. Epub 2008 Mar 13. AJNR Am J Neuroradiol. 2008. PMID: 18339719 Free PMC article. Review.
-
An image-processing toolset for diffusion tensor tractography.Magn Reson Imaging. 2007 Apr;25(3):365-76. doi: 10.1016/j.mri.2006.10.006. Epub 2006 Nov 20. Magn Reson Imaging. 2007. PMID: 17371726 Free PMC article. Review.
Cited by
-
lop-DWI: A Novel Scheme for Pre-Processing of Diffusion-Weighted Images in the Gradient Direction Domain.Front Neurol. 2015 Jan 12;5:290. doi: 10.3389/fneur.2014.00290. eCollection 2014. Front Neurol. 2015. PMID: 25628600 Free PMC article.
-
Changes in Cerebral Volume and White Matter Integrity in Adults on Hemodialysis and Relationship to Cognitive Function.Nephron. 2021;145(1):35-43. doi: 10.1159/000510614. Epub 2020 Oct 13. Nephron. 2021. PMID: 33049742 Free PMC article.
-
Frontostriatal white matter connectivity: age differences and associations with cognition and BOLD modulation.Neurobiol Aging. 2020 Oct;94:154-163. doi: 10.1016/j.neurobiolaging.2020.05.014. Epub 2020 Jun 7. Neurobiol Aging. 2020. PMID: 32623262 Free PMC article.
-
Multimodal brain imaging connectivity analyses of emotional and motivational deficits in depression among women.J Psychiatry Neurosci. 2021 Apr 12;46(2):E303-E312. doi: 10.1503/jpn.200074. J Psychiatry Neurosci. 2021. PMID: 33844485 Free PMC article.
-
Skeletal muscle diffusion tensor-MRI fiber tracking: rationale, data acquisition and analysis methods, applications and future directions.NMR Biomed. 2017 Mar;30(3):10.1002/nbm.3563. doi: 10.1002/nbm.3563. Epub 2016 Jun 3. NMR Biomed. 2017. PMID: 27257975 Free PMC article. Review.
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources