Cholesterol biosensor based on N-(2-aminoethyl)-3-aminopropyl-trimethoxysilane self-assembled monolayer
- PMID: 17335768
- DOI: 10.1016/j.ab.2007.01.029
Cholesterol biosensor based on N-(2-aminoethyl)-3-aminopropyl-trimethoxysilane self-assembled monolayer
Abstract
Cholesterol oxidase (ChOx) has been covalently immobilized onto two-dimensional self-assembled monolayer (SAM) of N-(2-aminoethyl)-3-aminopropyl-trimethoxysilane (AEAPTS) deposited on the indium-tin oxide (ITO) coated glass plates using N-ethyl-N'-(3-dimethylaminopropyl) carbodiimide and N-hydroxysuccinimide (EDC/NHS) chemistry. These ChO x/AEAPTS/ITO bioelectrodes are characterized using contact angle (CA) measurements, UV-visible spectroscopy, atomic force microscopy (AFM), electrochemical impedance technique, and Fourier transform infrared (FT-IR) technique. The covalently immobilized ChOx-modified AEAPTS bioelectrodes are used for the estimation of cholesterol in solution using UV-visible technique. These cholesterol sensing bioelectrodes show linearity as 50 to 500 mg/dl for cholesterol solution, detection limit as 25mg/dl, sensitivity as 4.499 x 10(-5) Abs (mg/dl)(-1), K(m) value as 58.137 mg/dl (1.5mM), apparent enzyme activity as 1.81 x 10(-3) U cm(-2), shelf life of approximately 10 weeks, and electrode reusability as 10 times.
Similar articles
-
Cholesterol biosensor based on electrophoretically deposited conducting polymer film derived from nano-structured polyaniline colloidal suspension.Anal Chim Acta. 2007 Oct 29;602(2):244-51. doi: 10.1016/j.aca.2007.09.028. Epub 2007 Sep 21. Anal Chim Acta. 2007. PMID: 17933610
-
Poly-(3-hexylthiophene) self-assembled monolayer based cholesterol biosensor using surface plasmon resonance technique.Biosens Bioelectron. 2007 May 15;22(11):2516-24. doi: 10.1016/j.bios.2006.10.011. Epub 2006 Nov 17. Biosens Bioelectron. 2007. PMID: 17113279
-
Cholesterol biosensor based on amino-undecanethiol self-assembled monolayer using surface plasmon resonance technique.Langmuir. 2007 Jun 19;23(13):7398-403. doi: 10.1021/la700350x. Epub 2007 May 25. Langmuir. 2007. PMID: 17523688
-
Ultrasensitive biochemical sensors based on microcantilevers of atomic force microscope.Anal Biochem. 2007 Apr 1;363(1):1-11. doi: 10.1016/j.ab.2006.12.010. Epub 2007 Jan 4. Anal Biochem. 2007. PMID: 17276384 Review. No abstract available.
-
Electrical properties of bioelectrodes.IEEE Trans Biomed Eng. 1984 Dec;31(12):827-32. doi: 10.1109/TBME.1984.325245. IEEE Trans Biomed Eng. 1984. PMID: 6396208 Review. No abstract available.
Cited by
-
Thiol-SAM Concentration Effect on the Performance of Interdigitated Electrode-Based Redox-Free Biosensors.Micromachines (Basel). 2024 Oct 12;15(10):1254. doi: 10.3390/mi15101254. Micromachines (Basel). 2024. PMID: 39459128 Free PMC article.
-
Bioelectrochemical biosensors for water quality assessment and wastewater monitoring.Open Life Sci. 2024 Aug 23;19(1):20220933. doi: 10.1515/biol-2022-0933. eCollection 2024. Open Life Sci. 2024. PMID: 39220594 Free PMC article. Review.
-
Estimation of the work of adhesion between ITO and polymer substrates: a surface thermodynamics approach.Turk J Chem. 2022 Nov 22;47(1):68-80. doi: 10.55730/1300-0527.3518. eCollection 2023. Turk J Chem. 2022. PMID: 37720870 Free PMC article.
-
Ultrasensitive Determination of Glial-Fibrillary-Acidic-Protein (GFAP) in Human Serum-Matrix with a Label-Free Impedimetric Immunosensor.Biosensors (Basel). 2022 Dec 14;12(12):1165. doi: 10.3390/bios12121165. Biosensors (Basel). 2022. PMID: 36551133 Free PMC article.
-
Non-Invasive Electrochemical Biosensors for TNF-α Cytokines Detection in Body Fluids.Front Bioeng Biotechnol. 2021 Sep 21;9:701045. doi: 10.3389/fbioe.2021.701045. eCollection 2021. Front Bioeng Biotechnol. 2021. PMID: 34621727 Free PMC article. Review.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical
Miscellaneous