Generating positive contrast from off-resonant spins with steady-state free precession magnetic resonance imaging: theory and proof-of-principle experiments
- PMID: 16912377
- DOI: 10.1088/0031-9155/51/17/006
Generating positive contrast from off-resonant spins with steady-state free precession magnetic resonance imaging: theory and proof-of-principle experiments
Abstract
It is well known that magnetic susceptibility variations lead to signal voids in MRI. However, recent work has shown that positive-contrast imaging of susceptibility-induced field variations can provide signal enhancements rather than signal losses. In this paper, we propose a new method for generating positive contrast from off-resonant spins with steady-state free precession (SSFP) magnetic resonance imaging. Based on theory and experiments, we demonstrate that positive-contrast images can be acquired in the presence of susceptibility-shift media with low flip angle excitations that are determined by the spin relaxation time constants of the imaging medium. Compared to other techniques, this technique is substantially faster and has low specific absorption rates, permitting high-field imaging. In addition to acquiring positive-contrast images, we also show that it is possible to suppress the imaging medium to desired levels; thereby allowing for simultaneous registration of the background details surrounding the susceptibility-shift media. Among practical applications, we anticipate that the proposed technique can potentially facilitate high field magnetic-resonance-based molecular imaging.
Similar articles
-
Factors influencing fast low angle positive contrast steady-state free precession (FLAPS) magnetic resonance imaging.Phys Med Biol. 2007 Jun 7;52(11):3261-73. doi: 10.1088/0031-9155/52/11/021. Epub 2007 May 15. Phys Med Biol. 2007. PMID: 17505101
-
Off-resonance positive contrast imaging of a passive endomyocardial catheter in swine.Phys Med Biol. 2008 Jul 7;53(13):N249-57. doi: 10.1088/0031-9155/53/13/N02. Epub 2008 Jun 19. Phys Med Biol. 2008. PMID: 18562781
-
Steady-state free precession with hyperpolarized 3He: experiments and theory.J Magn Reson. 2006 Nov;183(1):13-24. doi: 10.1016/j.jmr.2006.07.015. Epub 2006 Aug 4. J Magn Reson. 2006. PMID: 16890464
-
Pushing the sensitivity envelope of lanthanide-based magnetic resonance imaging (MRI) contrast agents for molecular imaging applications.Acc Chem Res. 2009 Jul 21;42(7):822-31. doi: 10.1021/ar800192p. Acc Chem Res. 2009. PMID: 19534516 Review.
-
Cardiac magnetic resonance imaging at 3.0 T.Top Magn Reson Imaging. 2007 Apr;18(2):95-104. doi: 10.1097/RMR.0b013e3180f617af. Top Magn Reson Imaging. 2007. PMID: 17621223 Review.
Cited by
-
Positive Contrast MRI Techniques for Visualization of Iron-Loaded Hernia Mesh Implants in Patients.PLoS One. 2016 May 18;11(5):e0155717. doi: 10.1371/journal.pone.0155717. eCollection 2016. PLoS One. 2016. PMID: 27192201 Free PMC article.
-
Imaging atherosclerosis and vulnerable plaque.J Nucl Med. 2010 May 1;51 Suppl 1(Suppl 1):51S-65S. doi: 10.2967/jnumed.109.068163. Epub 2010 Apr 15. J Nucl Med. 2010. PMID: 20395341 Free PMC article. Review.
-
High-sensitivity in vivo contrast for ultra-low field magnetic resonance imaging using superparamagnetic iron oxide nanoparticles.Sci Adv. 2020 Jul 17;6(29):eabb0998. doi: 10.1126/sciadv.abb0998. eCollection 2020 Jul. Sci Adv. 2020. PMID: 32733998 Free PMC article.
-
Positive contrast with alternating repetition time SSFP (PARTS): a fast imaging technique for SPIO-labeled cells.Magn Reson Med. 2010 Feb;63(2):427-37. doi: 10.1002/mrm.22241. Magn Reson Med. 2010. PMID: 20099331 Free PMC article.
-
The central signal singularity phenomenon in balanced SSFP and its application to positive-contrast imaging.Magn Reson Med. 2012 Jun;67(6):1673-83. doi: 10.1002/mrm.23156. Epub 2011 Oct 24. Magn Reson Med. 2012. PMID: 22025426 Free PMC article.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical