Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2006 Jun;52(6):1062-9.
doi: 10.1373/clinchem.2006.068577.

Increased integrity of free circulating DNA in sera of patients with colorectal or periampullary cancer: direct quantitative PCR for ALU repeats

Affiliations

Increased integrity of free circulating DNA in sera of patients with colorectal or periampullary cancer: direct quantitative PCR for ALU repeats

Naoyuki Umetani et al. Clin Chem. 2006 Jun.

Abstract

Background: Cell-free DNA circulating in blood is a candidate biomarker for malignant tumors. Unlike uniformly truncated DNA released from apoptotic nondiseased cells, DNA released from dead cancer cells varies in size. We developed a novel method to measure the ratio of longer to shorter DNA fragments (DNA integrity) in serum as a potential biomarker for patients with colorectal cancer (CRC) or periampullary cancers (PACs).

Methods: Sera from 32 patients with CRC (3 stage I, 14 stage II, 6 stage III, and 9 stage IV patients), 19 patients with PACs (2 stage I, 9 stage II, 1 stage III, and 7 stage IV patients), and 51 healthy volunteers were assessed by quantitative real-time PCR of ALU repeats (ALU-qPCR) with 2 sets of primers (115 and 247 bp) amplifying different lengths of DNA. We used serum directly as a template for ALU-qPCR without DNA purification. DNA integrity was determined as ratio of qPCR results of 247-bp ALU over 115-bp ALU.

Results: ALU-qPCR had a detection limit of 0.01 pg of DNA. Eliminating DNA purification reduced technical artifacts and reagent/labor costs. Serum DNA integrity was significantly increased for stage I/II and III/IV CRC and stage I/II and III/IV PACs (P = 0.002, P = 0.006, P = 0.022, and P <0.0001, respectively). ROC curves for detecting CRC and PACs had areas under the curves of 0.78 and 0.80, respectively.

Conclusions: Direct ALU-qPCR is a robust, highly sensitive, and high-throughput method to measure serum DNA integrity. DNA integrity is a potential serum biomarker for detection and evaluation of CRC and PACs.

PubMed Disclaimer

Similar articles

Cited by

Publication types

MeSH terms