Nanoliquid chromatography-mass spectrometry of oligosaccharides employing graphitized carbon chromatography on microchip with a high-accuracy mass analyzer
- PMID: 16196105
- DOI: 10.1002/elps.200500246
Nanoliquid chromatography-mass spectrometry of oligosaccharides employing graphitized carbon chromatography on microchip with a high-accuracy mass analyzer
Abstract
The nanoLC separations of oligosaccharides using microchip-based columns are described. Mixtures of alditols from mucins and human milk are separated on graphitized carbon. The nanoLC-MS device showed high mass accuracy for the oligosaccharides ranging between 1 and 6 ppm on routine analyses. The high mass accuracy readily allowed identification of oligosaccharide peaks and the determination of their compositions. High retention time reproducibility was exhibited by the microchip LC. Little variation was observed for standard sample either alone or in a complex heterogeneous mixture. The nanoLC-MS exhibits excellent capabilities in profiling mixtures of oligosaccharides.
Similar articles
-
Enhanced detection of sialylated and sulfated glycans with negative ion mode nanoliquid chromatography/mass spectrometry at high pH.Anal Chem. 2010 Feb 15;82(4):1470-7. doi: 10.1021/ac902602e. Anal Chem. 2010. PMID: 20092260
-
A strategy for annotating the human milk glycome.J Agric Food Chem. 2006 Oct 4;54(20):7471-80. doi: 10.1021/jf0615810. J Agric Food Chem. 2006. PMID: 17002410
-
Daily variations in oligosaccharides of human milk determined by microfluidic chips and mass spectrometry.J Agric Food Chem. 2008 Jan 23;56(2):618-26. doi: 10.1021/jf071972u. Epub 2007 Dec 19. J Agric Food Chem. 2008. PMID: 18088092
-
High-throughput and high-sensitivity nano-LC/MS and MS/MS for O-glycan profiling.Methods Mol Biol. 2009;534:117-31. doi: 10.1007/978-1-59745-022-5_9. Methods Mol Biol. 2009. PMID: 19277531 Review.
-
Microfluidic chip-based liquid chromatography coupled to mass spectrometry for determination of small molecules in bioanalytical applications.Electrophoresis. 2012 Feb;33(4):635-43. doi: 10.1002/elps.201100380. Electrophoresis. 2012. PMID: 22451056 Review.
Cited by
-
Profiling the glycoforms of the intact alpha subunit of recombinant human chorionic gonadotropin by high-resolution capillary electrophoresis-mass spectrometry.Anal Chem. 2009 Nov 1;81(21):8900-7. doi: 10.1021/ac901506p. Anal Chem. 2009. PMID: 19817480 Free PMC article.
-
A glycomics platform for the analysis of permethylated oligosaccharide alditols.J Am Soc Mass Spectrom. 2007 Oct;18(10):1799-812. doi: 10.1016/j.jasms.2007.07.016. Epub 2007 Jul 26. J Am Soc Mass Spectrom. 2007. PMID: 17719235 Free PMC article.
-
Characterization of isomeric glycan structures by LC-MS/MS.Electrophoresis. 2017 Sep;38(17):2100-2114. doi: 10.1002/elps.201700042. Epub 2017 May 17. Electrophoresis. 2017. PMID: 28370073 Free PMC article. Review.
-
Analysis of Glycosaminoglycans Using Mass Spectrometry.Curr Proteomics. 2011;8(4):325-336. doi: 10.2174/157016411798220871. Curr Proteomics. 2011. PMID: 25705143 Free PMC article.
-
Human milk oligosaccharides: evolution, structures and bioselectivity as substrates for intestinal bacteria.Nestle Nutr Workshop Ser Pediatr Program. 2008;62:205-18; discussion 218-22. doi: 10.1159/000146322. Nestle Nutr Workshop Ser Pediatr Program. 2008. PMID: 18626202 Free PMC article. Review.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources