Polyetheretherketone as a biomaterial for spinal applications
- PMID: 16115677
- DOI: 10.1016/j.biomaterials.2005.07.011
Polyetheretherketone as a biomaterial for spinal applications
Abstract
Threaded lumbar interbody spinal fusion devices (TIBFD) made from titanium have been reported to be 90% effective for single-level lumbar interbody fusion, although radiographic determination of fusion has been intensely debated in the literature. Using blinded radiographic, biomechanic, histologic, and statistical measures, we evaluated a radiolucent polyetheretherketone (PEEK)-threaded interbody fusion device packed with autograft or rhBMP-2 on an absorbable collagen sponge in 13 sheep at 6 months. Radiographic fusion, increased spinal level biomechanical stiffness, and histologic fusion were demonstrated for the PEEK cages filled with autograft or rhBMP-2 on a collagen sponge. No device degradation or wear debris was observed. Only mild chronic inflammation consisting of a few macrophages was observed in peri-implant tissues. Based on these results, the polymeric biomaterial PEEK may be a useful biomaterial for interbody fusion cages due to the polymer's increased radiolucency and decreased stiffness.
Similar articles
-
Histologic evaluation of the efficacy of rhBMP-2 compared with autograft bone in sheep spinal anterior interbody fusion.Spine (Phila Pa 1976). 2002 Mar 15;27(6):567-75. doi: 10.1097/00007632-200203150-00003. Spine (Phila Pa 1976). 2002. PMID: 11884903
-
rhBMP-2 (ACS and CRM formulations) overcomes pseudarthrosis in a New Zealand white rabbit posterolateral fusion model.Spine (Phila Pa 1976). 2007 May 15;32(11):1206-13. doi: 10.1097/BRS.0b013e318054721e. Spine (Phila Pa 1976). 2007. PMID: 17495777
-
Biomechanical rationale for using polyetheretherketone (PEEK) spacers for lumbar interbody fusion-A finite element study.Spine (Phila Pa 1976). 2006 Dec 15;31(26):E992-8. doi: 10.1097/01.brs.0000250177.84168.ba. Spine (Phila Pa 1976). 2006. PMID: 17172990
-
Titanium vs. polyetheretherketone (PEEK) interbody fusion: Meta-analysis and review of the literature.J Clin Neurosci. 2017 Oct;44:23-29. doi: 10.1016/j.jocn.2017.06.062. Epub 2017 Jul 21. J Clin Neurosci. 2017. PMID: 28736113 Review.
-
Bone morphogenetic proteins for spinal fusion.Spine J. 2005 Nov-Dec;5(6 Suppl):240S-249S. doi: 10.1016/j.spinee.2005.02.014. Spine J. 2005. PMID: 16291119 Review.
Cited by
-
A self-assembling graphene oxide coating for enhanced bactericidal and osteogenic properties of poly-ether-ether-ketone.Front Bioeng Biotechnol. 2024 May 6;12:1378681. doi: 10.3389/fbioe.2024.1378681. eCollection 2024. Front Bioeng Biotechnol. 2024. PMID: 38774816 Free PMC article.
-
A Comparison between Structural Allografts and Polyetheretherketone Interbody Spacers Used in Anterior Cervical Discectomy and Fusion: A Systematic Review and Meta-analysis.Asian Spine J. 2024 Feb;18(1):124-136. doi: 10.31616/asj.2023.0128. Epub 2024 Jan 30. Asian Spine J. 2024. PMID: 38287665 Free PMC article.
-
Mapping Subchondral Bone Density Distribution in the Canine C6-C7 Vertebral Endplates: A CT-OAM Study.Animals (Basel). 2023 Nov 7;13(22):3432. doi: 10.3390/ani13223432. Animals (Basel). 2023. PMID: 38003050 Free PMC article.
-
The All-on-4 Concept Using Polyetheretherketone (PEEK)-Acrylic Resin Prostheses: Follow-Up Results of the Development Group at 5 Years and the Routine Group at One Year.Biomedicines. 2023 Nov 9;11(11):3013. doi: 10.3390/biomedicines11113013. Biomedicines. 2023. PMID: 38002014 Free PMC article.
-
State-of-the-art polyetheretherketone three-dimensional printing and multifunctional modification for dental implants.Front Bioeng Biotechnol. 2023 Oct 19;11:1271629. doi: 10.3389/fbioe.2023.1271629. eCollection 2023. Front Bioeng Biotechnol. 2023. PMID: 37929192 Free PMC article. Review.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources