Toward understanding the risk of secondary airborne infection: emission of respirable pathogens
- PMID: 15764538
- PMCID: PMC7196697
- DOI: 10.1080/15459620590918466
Toward understanding the risk of secondary airborne infection: emission of respirable pathogens
Abstract
Certain respiratory tract infections are transmitted through air. Coughing and sneezing by an infected person can emit pathogen-containing particles with diameters less than 10 microm that can reach the alveolar region. Based on our analysis of the sparse literature on respiratory aerosols, we estimated that emitted particles quickly decrease in diameter due to water loss to one-half the initial values, and that in one cough the volume in particles with initial diameters less than 20 microm is 60 x 10(-8) mL. The pathogen emission rate from a source case depends on the frequency of expiratory events, the respirable particle volume, and the pathogen concentration in respiratory fluid. Viable airborne pathogens are removed by exhaust ventilation, particle settling, die-off, and air disinfection methods; each removal mechanism can be assigned a first-order rate constant. The pathogen concentration in well-mixed room air depends on the emission rate, the size distribution of respirable particles carrying pathogens, and the removal rate constants. The particle settling rate and the alveolar deposition fraction depend on particle size. Given these inputs plus a susceptible person's breathing rate and exposure duration to room air, an expected alveolar dosemicrois estimated. If the infectious dose is one organism, as appears to be true for tuberculosis, infection risk is estimated by the expression: R = 1-exp(-micro). Using published tuberculosis data concerning cough frequency, bacilli concentration in respiratory fluid, and die-off rate, we illustrate the model via a plausible scenario for a person visiting the room of a pulmonary tuberculosis case. We suggest that patients termed "superspreaders" or "dangerous disseminators" are those infrequently encountered persons with high values of cough and/or sneeze frequency, elevated pathogen concentration in respiratory fluid, and/or increased respirable aerosol volume per expiratory event such that their pathogen emission rate is much higher than average.
Figures
Similar articles
-
Computational fluid dynamics study on the influence of an alternate ventilation configuration on the possible flow path of infectious cough aerosols in a mock airborne infection isolation room.Sci Technol Built Environ. 2016;23(2):355-366. doi: 10.1080/23744731.2016.1222212. Epub 2016 Sep 19. Sci Technol Built Environ. 2016. PMID: 28736744 Free PMC article.
-
NTP Toxicity Study Report on the atmospheric characterization, particle size, chemical composition, and workplace exposure assessment of cellulose insulation (CELLULOSEINS).Toxic Rep Ser. 2006 Aug;(74):1-62, A1-C2. Toxic Rep Ser. 2006. PMID: 17160106
-
Quantitative Microbial Risk Assessment for Airborne Transmission of SARS-CoV-2 via Breathing, Speaking, Singing, Coughing, and Sneezing.Environ Health Perspect. 2021 Apr;129(4):47002. doi: 10.1289/EHP7886. Epub 2021 Apr 1. Environ Health Perspect. 2021. PMID: 33793301 Free PMC article.
-
Aerosol transmission of infectious disease.J Occup Environ Med. 2015 May;57(5):501-8. doi: 10.1097/JOM.0000000000000448. J Occup Environ Med. 2015. PMID: 25816216 Review.
-
Is cough really necessary for TB transmission?Tuberculosis (Edinb). 2019 Jul;117:31-35. doi: 10.1016/j.tube.2019.05.003. Epub 2019 May 28. Tuberculosis (Edinb). 2019. PMID: 31378265 Free PMC article. Review.
Cited by
-
Model analysis of fomite mediated influenza transmission.PLoS One. 2012;7(12):e51984. doi: 10.1371/journal.pone.0051984. Epub 2012 Dec 27. PLoS One. 2012. PMID: 23300585 Free PMC article.
-
Respiratory source control using a surgical mask: An in vitro study.J Occup Environ Hyg. 2016 Jul;13(7):569-76. doi: 10.1080/15459624.2015.1043050. J Occup Environ Hyg. 2016. PMID: 26225807 Free PMC article.
-
Transmission of COVID-19 virus by droplets and aerosols: A critical review on the unresolved dichotomy.Environ Res. 2020 Sep;188:109819. doi: 10.1016/j.envres.2020.109819. Epub 2020 Jun 13. Environ Res. 2020. PMID: 32569870 Free PMC article. Review.
-
Modeling the viral load dependence of residence times of virus-laden droplets from COVID-19-infected subjects in indoor environments.Indoor Air. 2021 Nov;31(6):1786-1797. doi: 10.1111/ina.12868. Epub 2021 Jun 12. Indoor Air. 2021. PMID: 34118165 Free PMC article.
-
A dynamical overview of droplets in the transmission of respiratory infectious diseases.Phys Fluids (1994). 2021 Mar 1;33(3):031301. doi: 10.1063/5.0039487. Epub 2021 Mar 17. Phys Fluids (1994). 2021. PMID: 33897237 Free PMC article. Review.
References
-
- Centers for Disease Control and Prevention (CDC) : Guideline for Isolation Precautions in Hospitals, Part II. Recommendations for Isolation Precautions in Hospitals. J.s. Garner and the Hospital Infection Control Practices Advisory Committee; (1997), http://www.cdc.gov/ncidod/hip/ISOLAT/isopart2.htm (accessed November 10, 2004).
-
- Centers for Disease Control and Prevention (CDC) : Guidelines for preventing the transmission of Mycobacterium tuberculosis in health-care facilities. 1994. MMWR 43: 1–132, (1994). p. 4. - PubMed
-
- Wells W.F.: On air-borne infection. Study II. Droplets and droplet nuclei. Am. J. Hyg. 20: 611–618 (1934).
-
- Hinds W.C.: Aerosol Technology. New York: John Wiley & Sons. Inc., 57–58: 211–221 (1982).
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources