Comparison of multifrequency bioelectrical impedance analysis with dual-energy X-ray absorptiometry for assessment of percentage body fat in a large, healthy population
- PMID: 15640463
- DOI: 10.1093/ajcn/81.1.74
Comparison of multifrequency bioelectrical impedance analysis with dual-energy X-ray absorptiometry for assessment of percentage body fat in a large, healthy population
Abstract
Background: Bioelectrical impedance analysis (BIA) is widely used in clinics and research to measure body composition. However, the results of BIA validation with reference methods are contradictory, and few data are available on the influence of adiposity on the measurement of body composition by BIA.
Objective: The goal was to determine the effects of sex and adiposity on the difference in percentage body fat (%BF) predicted by BIA compared with dual-energy X-ray absorptiometry (DXA).
Design: A total of 591 healthy subjects were recruited in Newfoundland and Labrador. %BF was predicted by using BIA and was compared with that measured by DXA. Methods agreement was assessed by Pearson's correlation and Bland and Altman analysis. Differences in %BF among groups based on sex and adiposity were analyzed by using one-factor analysis of variance with Bonferroni correction.
Results: Correlations between BIA and DXA were 0.88 for the whole population, 0.78 for men, and 0.85 for women. The mean %BF determined by BIA (32.89 +/- 8.00%) was significantly lower than that measured by DXA (34.72 +/- 8.66%). The cutoffs were sex specific. BIA overestimated %BF by 3.03% and 4.40% when %BF was <15% in men and <25% in women, respectively, and underestimated %BF by 4.32% and 2.71% when %BF was >25% in men and >33% in women, respectively.
Conclusions: BIA is a good alternative for estimating %BF when subjects are within a normal body fat range. BIA tends to overestimate %BF in lean subjects and underestimate %BF in obese subjects.
Similar articles
-
Comparison of Standing Posture Bioelectrical Impedance Analysis with DXA for Body Composition in a Large, Healthy Chinese Population.PLoS One. 2016 Jul 28;11(7):e0160105. doi: 10.1371/journal.pone.0160105. eCollection 2016. PLoS One. 2016. PMID: 27467065 Free PMC article.
-
Comparison of body composition methods during weight loss in obese women using herbal formula.Am J Chin Med. 2005;33(6):851-8. doi: 10.1142/S0192415X05003454. Am J Chin Med. 2005. PMID: 16355441
-
Validity of electrical impedance myography to estimate percent body fat: comparison to bio-electrical impedance and dual-energy X-ray absorptiometry.J Sports Med Phys Fitness. 2019 Apr;59(4):632-639. doi: 10.23736/S0022-4707.18.08505-5. Epub 2018 Jul 18. J Sports Med Phys Fitness. 2019. PMID: 30024123
-
What About Water? Implications for Body Composition Assessment in Military Personnel.J Strength Cond Res. 2024 Sep 1;38(9):e534-e540. doi: 10.1519/JSC.0000000000004840. Epub 2024 Jul 23. J Strength Cond Res. 2024. PMID: 39074192 Review.
-
Body composition assessment in individuals with class II/III obesity: a narrative review.BMC Nutr. 2024 Oct 22;10(1):142. doi: 10.1186/s40795-024-00913-2. BMC Nutr. 2024. PMID: 39438968 Free PMC article. Review.
Cited by
-
Percent body fat is a better predictor of cardiovascular risk factors than body mass index.Braz J Med Biol Res. 2012 Jul;45(7):591-600. doi: 10.1590/s0100-879x2012007500059. Epub 2012 Apr 19. Braz J Med Biol Res. 2012. PMID: 22510779 Free PMC article.
-
Serum metabolic biomarkers distinguish metabolically healthy peripherally obese from unhealthy centrally obese individuals.Nutr Metab (Lond). 2016 May 12;13:33. doi: 10.1186/s12986-016-0095-9. eCollection 2016. Nutr Metab (Lond). 2016. PMID: 27175209 Free PMC article.
-
Nutrient intake, body composition, blood cholesterol and glucose levels among adult Asian Indians in the United States.J Immigr Minor Health. 2007 Jul;9(3):171-8. doi: 10.1007/s10903-006-9027-5. J Immigr Minor Health. 2007. PMID: 17279330
-
Validity of leg-to-leg bioelectrical impedance analysis to estimate body fat in obesity.Obes Surg. 2011 Jul;21(7):917-23. doi: 10.1007/s11695-010-0296-7. Obes Surg. 2011. PMID: 20936394
-
Comparison of Dual-Energy X-ray Absorptiometry and Bioelectrical Impedance Analysis in the Assessment of Body Composition in Women with Anorexia Nervosa upon Admission and Discharge from an Inpatient Specialist Unit.Int J Environ Res Public Health. 2021 Oct 29;18(21):11388. doi: 10.3390/ijerph182111388. Int J Environ Res Public Health. 2021. PMID: 34769915 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Miscellaneous