Hydroxyapatite-coated prostheses in total hip and knee arthroplasty
- PMID: 15523030
- DOI: 10.2106/00004623-200411000-00029
Hydroxyapatite-coated prostheses in total hip and knee arthroplasty
Abstract
Hydroxyapatite-coated implants have demonstrated extensive bone apposition in animal models. The osseous interface develops even in the presence of gaps of 1 mm and relative motion of up to 500 mum. Development of implant-bone interfacial strength is due to the biological effects of released calcium and phosphate ions, although surface roughness leads to increased interface strength in the absence of interface gaps. The clinical results at fifteen years after total hip replacements have demonstrated that hydroxyapatite-coated femoral stems perform as well as, and possibly better than, other types of cementless devices, with the added benefit of providing a seal against wear debris. Hydroxyapatite-coated acetabular components must have a mechanical interlock with bone in order to take advantage of the coating effects. Clinical analyses of these types of designs at seven years have indicated good survivorship. The performance of a hydroxyapatite-coated implant depends on coating properties (thickness, porosity, hydroxyapatite content, and crystallinity), implant roughness, and overall design. The most reliable predictor of the performance of a device is success in long-term clinical studies.
Similar articles
-
A randomized trial of hydroxyapatite coated prostheses in total hip arthroplasty.Clin Orthop Relat Res. 1999 Sep;(366):120-32. doi: 10.1097/00003086-199909000-00016. Clin Orthop Relat Res. 1999. PMID: 10627726 Clinical Trial.
-
[Long-term experience with the combined ARBOND hydroxyapatite coating in implant osteointegration].Acta Chir Orthop Traumatol Cech. 2009 Jun;76(3):172-8. Acta Chir Orthop Traumatol Cech. 2009. PMID: 19595277 Czech.
-
Fixation of acetabular cups without cement in total hip arthroplasty. A comparison of three different implant surfaces at a minimum duration of follow-up of five years.J Bone Joint Surg Am. 1998 Aug;80(8):1175-85. doi: 10.2106/00004623-199808000-00011. J Bone Joint Surg Am. 1998. PMID: 9730127
-
Component selection in revision total hip arthroplasty.Orthop Clin North Am. 2014 Jul;45(3):275-86. doi: 10.1016/j.ocl.2014.03.001. Orthop Clin North Am. 2014. PMID: 24975757 Review.
-
Hydroxyapatite-coated tapered cementless femoral components in total hip arthroplasty.J Arthroplasty. 2007 Jun;22(4 Suppl 1):71-4. doi: 10.1016/j.arth.2007.01.019. J Arthroplasty. 2007. PMID: 17570282 Review.
Cited by
-
Femoral revision with an extensively hydroxyapatite-coated femoral component.HSS J. 2008 Feb;4(1):55-61. doi: 10.1007/s11420-007-9068-x. Epub 2007 Dec 1. HSS J. 2008. PMID: 18751863 Free PMC article.
-
Controlled size and morphology of EDTMP-doped hydroxyapatite nanoparticles as model for 153Samarium-EDTMP doping.J Mater Sci Mater Med. 2008 Sep;19(9):2993-3003. doi: 10.1007/s10856-008-3426-1. Epub 2008 Mar 25. J Mater Sci Mater Med. 2008. PMID: 18360794
-
Comparison of mesenchymal stem cell and osteosarcoma cell adhesion to hydroxyapatite.J Mater Sci Mater Med. 2008 Dec;19(12):3567-74. doi: 10.1007/s10856-008-3525-z. Epub 2008 Jul 15. J Mater Sci Mater Med. 2008. PMID: 18626747 Free PMC article.
-
Calcium Phosphate Bioceramics: A Review of Their History, Structure, Properties, Coating Technologies and Biomedical Applications.Materials (Basel). 2017 Mar 24;10(4):334. doi: 10.3390/ma10040334. Materials (Basel). 2017. PMID: 28772697 Free PMC article. Review.
-
The Evolution, Current Indications and Outcomes of Cementless Total Knee Arthroplasty.J Clin Med. 2022 Nov 8;11(22):6608. doi: 10.3390/jcm11226608. J Clin Med. 2022. PMID: 36431091 Free PMC article. Review.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources