Automated multi-well device to measure transepithelial electrical resistances under physiological conditions
- PMID: 15517971
- DOI: 10.2144/04374ST03
Automated multi-well device to measure transepithelial electrical resistances under physiological conditions
Abstract
Measurement of transendothelial or transepithelial electrical resistances (TERs) is a straightforward in situ experimental approach to monitor the expression or modulation of barrier-forming cell-to-cell contacts (tight junctions) in cultured cells grown on porous filters. Although widely accepted, there is currently no device available to automatically measure the time course of TERs under ordinary cell culture conditions (37 degrees C, 5% or 10% CO2). This paper describes a development from our laboratory that is capable of following in parallel the TERs of several filter-grown cell layers with time and in an entirely computer-controlled fashion. The cell cultures can be followed even in long-term experiments without any manual assistance or opening of the incubator Besides reading TER values, this approach also returns the electrical capacitance of the cell layers, which is indicative of the expression of microvilli and other membrane extrusions. The device is based on reading the frequencydependent impedance of the cell layer, followed by equivalent circuit modeling to extract the cell-related parameters. It is compatible with several multi-well formats (up to 96 wells) and controlled by custom-designed software that reads, analyzes, and presents the data.
Similar articles
-
Impedance analysis of epithelial and endothelial cell monolayers cultured on gold surfaces.J Biochem Biophys Methods. 1996 Jul 10;32(3):151-70. doi: 10.1016/0165-022x(96)00005-x. J Biochem Biophys Methods. 1996. PMID: 8844323
-
Cell-substrate contact: another factor may influence transepithelial electrical resistance of cell layers cultured on permeable filters.Exp Cell Res. 1999 Aug 1;250(2):576-80. doi: 10.1006/excr.1999.4538. Exp Cell Res. 1999. PMID: 10413610
-
A Simple Approach to Perform TEER Measurements Using a Self-Made Volt-Amperemeter with Programmable Output Frequency.J Vis Exp. 2019 Oct 5;(152). doi: 10.3791/60087. J Vis Exp. 2019. PMID: 31633685
-
TEER measurement techniques for in vitro barrier model systems.J Lab Autom. 2015 Apr;20(2):107-26. doi: 10.1177/2211068214561025. Epub 2015 Jan 13. J Lab Autom. 2015. PMID: 25586998 Free PMC article. Review.
-
Experimental tools to monitor the dynamics of endothelial barrier function: a survey of in vitro approaches.Cell Tissue Res. 2014 Mar;355(3):485-514. doi: 10.1007/s00441-014-1810-3. Epub 2014 Mar 2. Cell Tissue Res. 2014. PMID: 24585359 Review.
Cited by
-
RhoGDI1 regulates cell-cell junctions in polarized epithelial cells.Front Cell Dev Biol. 2024 Jul 17;12:1279723. doi: 10.3389/fcell.2024.1279723. eCollection 2024. Front Cell Dev Biol. 2024. PMID: 39086660 Free PMC article.
-
Glycogen myophosphorylase loss causes increased dependence on glucose in iPSC-derived retinal pigment epithelium.J Biol Chem. 2024 Aug;300(8):107569. doi: 10.1016/j.jbc.2024.107569. Epub 2024 Jul 14. J Biol Chem. 2024. PMID: 39009342 Free PMC article.
-
A Microphysiological System for Studying Barrier Health of Live Tissues in Real Time.Res Sq [Preprint]. 2024 Apr 12:rs.3.rs-4078220. doi: 10.21203/rs.3.rs-4078220/v1. Res Sq. 2024. PMID: 38659839 Free PMC article. Preprint.
-
SARS-CoV-2 envelope protein impairs airway epithelial barrier function and exacerbates airway inflammation via increased intracellular Cl- concentration.Signal Transduct Target Ther. 2024 Mar 25;9(1):74. doi: 10.1038/s41392-024-01753-z. Signal Transduct Target Ther. 2024. PMID: 38528022 Free PMC article.
-
Innovative electrode and chip designs for transendothelial electrical resistance measurements in organs-on-chips.Lab Chip. 2024 Feb 27;24(5):1121-1134. doi: 10.1039/d3lc00901g. Lab Chip. 2024. PMID: 38165817 Free PMC article. Review.
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources