An automated microscope for cytologic research a preliminary evaluation
- PMID: 1254907
- DOI: 10.1177/24.1.1254907
An automated microscope for cytologic research a preliminary evaluation
Abstract
A research-oriented system for automated microscopy is described from an operational point of view. The system consists of a microscope, a TV camera, an automatic cell finder and a servo-driven computer controlled stage. The system is interfaced to a NOVA 840 computer having 112,000 words of 16-bit core memory and extensive peripherals. It is capable of performing a wide variety of image processing tasks and is being used to study various aspects of automated microscopy, with applications in, but not limited to, cytology. Results of preliminary performance evaluations are given.
Similar articles
-
FAZYTAN: a system for fast automated cell segmentation, cell image analysis and feature extraction based on TV-image pickup and parallel processing.Anal Quant Cytol. 1980 Mar-Apr;2(1):25-40. Anal Quant Cytol. 1980. PMID: 6990846
-
Semiautomatic microscopy as a tool for cytologists.Anal Quant Cytol Histol. 1986 Jun;8(2):116-27. Anal Quant Cytol Histol. 1986. PMID: 2425824
-
Use of the MAGISCAN image analyser in automated uterine cancer cytology.Anal Quant Cytol. 1980 Sep;2(3):195-202. Anal Quant Cytol. 1980. PMID: 7425440
-
Automation of the analysis of cell images.Anal Quant Cytol. 1980 Mar-Apr;2(1):1-14. Anal Quant Cytol. 1980. PMID: 6103684 Review.
-
Standardization of dyes and stains for automated cell pattern recognition.Anal Quant Cytol Histol. 1985 Mar;7(1):6-30. Anal Quant Cytol Histol. 1985. PMID: 2408527 Review.
Cited by
-
"Blind focusing": an objective method for avoiding errors of focus at the television texture analysis system (TAS).Histochemistry. 1979 Sep;63(2):221-6. doi: 10.1007/BF00644544. Histochemistry. 1979. PMID: 500407
-
Image Quality Ranking Method for Microscopy.Sci Rep. 2016 Jul 1;6:28962. doi: 10.1038/srep28962. Sci Rep. 2016. PMID: 27364703 Free PMC article.
-
A Review on Microscopic Visual Servoing for Micromanipulation Systems: Applications in Micromanufacturing, Biological Injection, and Nanosensor Assembly.Micromachines (Basel). 2019 Dec 2;10(12):843. doi: 10.3390/mi10120843. Micromachines (Basel). 2019. PMID: 31810244 Free PMC article. Review.
-
No-Reference Quality Assessment Method for Blurriness of SEM Micrographs with Multiple Texture.Scanning. 2019 Jun 2;2019:4271761. doi: 10.1155/2019/4271761. eCollection 2019. Scanning. 2019. PMID: 31281563 Free PMC article.
-
Infrared light field imaging system free of fixed-pattern noise.Sci Rep. 2017 Oct 12;7(1):13040. doi: 10.1038/s41598-017-13595-7. Sci Rep. 2017. PMID: 29026212 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources