Abstract
A rapid immunodiagnostic test (ICT Malaria PfTest) has been developed by ICT Diagnostics (Sydney, Australia) for the diagnosis of Plasmodium falciparum infection. The test is an antigen capture assay based on the detection of P. falciparum histidine-rich protein 2 in peripheral blood. This study was undertaken to assess the performance and usefulness of the test as a diagnostic method in highly malarious, inaccessible forested villages of Mandla district, central India. In all, 353 patients with fever were scanned by the test in parallel with thick blood film examination. The sensitivity and specificity were 100% and 84.5%, respectively. The whole test took about 5 min. The test results became negative in most cases (70%) within 7 d after initiation of curative chemotherapy. The test is simple, easy to learn and accurate, and may prove to be an important tool in the battle against falciparum malaria.
Similar articles
-
A rapid immunochromatographic test (ICT) for diagnosis of Plasmodium falciparum.Diagn Microbiol Infect Dis. 1998 Apr;30(4):257-60. doi: 10.1016/s0732-8893(98)00003-0. Diagn Microbiol Infect Dis. 1998. PMID: 9582585
-
The ParaSight-F dipstick test as a routine diagnostic tool for malaria in Sri Lanka.Trans R Soc Trop Med Hyg. 1997 Jul-Aug;91(4):398-402. doi: 10.1016/s0035-9203(97)90255-8. Trans R Soc Trop Med Hyg. 1997. PMID: 9373632
-
The use of a dipstick antigen-capture assay for the diagnosis of Plasmodium falciparum infection in a remote forested area of central India.Am J Trop Med Hyg. 1997 Feb;56(2):188-91. doi: 10.4269/ajtmh.1997.56.188. Am J Trop Med Hyg. 1997. PMID: 9080879
-
Diagnosis of malaria by detection of Plasmodium falciparum HRP-2 antigen with a rapid dipstick antigen-capture assay.Lancet. 1994 Mar 5;343(8897):564-8. doi: 10.1016/s0140-6736(94)91520-2. Lancet. 1994. PMID: 7906328
-
Clinical trials of a new immunochromatographic test for diagnosis of Plasmodium falciparum malaria in Goa.Indian J Malariol. 1996 Dec;33(4):166-72. Indian J Malariol. 1996. PMID: 9125830 Clinical Trial.
Cited by
-
Persistent ICT malaria P.f/P.v panmalarial and HRP2 antigen reactivity after treatment of Plasmodium falciparum malaria is associated with gametocytemia and results in false-positive diagnoses of Plasmodium vivax in convalescence.J Clin Microbiol. 2001 Mar;39(3):1025-31. doi: 10.1128/JCM.39.3.1025-1031.2001. J Clin Microbiol. 2001. PMID: 11230422 Free PMC article.
-
Plasmodium falciparum histidine-rich protein 2-based immunocapture diagnostic assay for malaria: cross-reactivity with rheumatoid factors.J Clin Microbiol. 2000 Mar;38(3):1184-6. doi: 10.1128/JCM.38.3.1184-1186.2000. J Clin Microbiol. 2000. PMID: 10699018 Free PMC article.
-
Rapid diagnostic tests for diagnosing uncomplicated P. falciparum malaria in endemic countries.Cochrane Database Syst Rev. 2011 Jul 6;2011(7):CD008122. doi: 10.1002/14651858.CD008122.pub2. Cochrane Database Syst Rev. 2011. PMID: 21735422 Free PMC article. Review.
-
Rapid diagnosis of vivax malaria by the SD Bioline Malaria Antigen test when thrombocytopenia is present.J Clin Microbiol. 2008 Mar;46(3):939-42. doi: 10.1128/JCM.02110-07. Epub 2007 Dec 26. J Clin Microbiol. 2008. PMID: 18160449 Free PMC article.
-
Battling malaria iceberg incorporating strategic reforms in achieving Millennium Development Goals & malaria elimination in India.Indian J Med Res. 2012 Dec;136(6):907-25. Indian J Med Res. 2012. PMID: 23391787 Free PMC article. Review.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources