Chronic electrical stimulation of the auditory nerve at high stimulus rates: a physiological and histopathological study
- PMID: 9083801
- DOI: 10.1016/s0378-5955(96)00193-1
Chronic electrical stimulation of the auditory nerve at high stimulus rates: a physiological and histopathological study
Abstract
A major factor associated with recent improvements in the clinical performance of cochlear implant patients has been the development of speech-processing strategies based on high stimulation rates. While these processing strategies show clear clinical advantage, we know little of their long-term safety implications. The present study was designed to evaluate the physiological and histopathological effects of long-term intracochlear electrical stimulation using these high rates. Thirteen normal-hearing adult cats were bilaterally implanted with scala tympani electrode arrays and unilaterally stimulated for periods of up to 2100 h using either two pairs of bipolar or three monopolar stimulating electrodes. Stimuli consisted of short duration (25-50 microseconds/phase) charge-balanced biphasic current pulses presented at 1000 pulses per second (pps) per channel for monopolar stimulation, and 2000 pps/channel for bipolar stimulation. The electrodes were shorted between current pulses to minimize any residual direct current, and the pulse trains were presented using a 50% duty cycle (500 ms on; 500 ms off) in order to simulate speech. Both acoustic (ABR) and electrical (EABR) auditory brainstem responses were recorded periodically during the chronic stimulation program. All cochleas showed an increase in the click-evoked ABR threshold following implant surgery; however, recovery to near-normal levels occurred in approximately half of the stimulated cochleas 1 month post-operatively. The use of frequency-specific stimuli indicated that the most extensive hearing loss generally occurred in the high-frequency basal region of the cochlea (12 and 24 kHz) adjacent to the stimulating electrode. However, thresholds at lower frequencies (2, 4 and 8 kHz), appeared at near-normal levels despite long-term electrode implantation and electrical stimulation. Our longitudinal EABR results showed a statistically significant increase in threshold in nearly 40% of the chronically stimulated electrodes evaluated; however, the gradient of the EABR input/output (I/O) function (evoked potential response amplitude versus stimulus current) generally remained quite stable throughout the chronic stimulation period. Histopathological examination of the cochleas showed no statistically significant difference in ganglion cell densities between cochleas using monopolar and bipolar electrode configurations (P = 0.67), and no evidence of cochlear damage caused by high-rate electrical stimulation when compared with control cochleas. Indeed, there was no statistically significant relationship between spiral ganglion cell density and electrical stimulation (P = 0.459), or between the extent of loss of inner (IHC, P = 0.86) or outer (OHC, P = 0.30) hair cells and electrical stimulation. Spiral ganglion cell loss was, however, influenced by the degree of inflammation (P = 0.016) and electrode insertion trauma. These histopathological findings were consistent with the physiological data. Finally, electrode impedance, measured at completion of the chronic stimulation program, showed close correlation with the degree of tissue response adjacent to the electrode array. These results indicated that chronic intracochlear electrical stimulation, using carefully controlled charge-balanced biphasic current pulses at stimulus rates of up to 2000 pps/channel, does not appear to adversely affect residual auditory nerve elements or the cochlea in general. This study provides an important basis for the safe application of improved speech-processing strategies based on high-rate electrical stimulation.
Similar articles
-
Cochlear pathology following chronic electrical stimulation of the auditory nerve. I: Normal hearing kittens.Hear Res. 1992 Sep;62(1):63-81. doi: 10.1016/0378-5955(92)90203-y. Hear Res. 1992. PMID: 1429252
-
Cochlear pathology following chronic electrical stimulation of the auditory nerve: II. Deafened kittens.Hear Res. 1994 Dec;81(1-2):150-66. doi: 10.1016/0378-5955(94)90162-7. Hear Res. 1994. PMID: 7737922
-
Chronic electrical stimulation of the auditory nerve in cats. Physiological and histopathological results.Acta Otolaryngol Suppl. 1983;399:19-31. doi: 10.3109/00016488309105589. Acta Otolaryngol Suppl. 1983. PMID: 6316712
-
Electrical stimulation of the auditory nerve: the coding of frequency, the perception of pitch and the development of cochlear implant speech processing strategies for profoundly deaf people.Clin Exp Pharmacol Physiol. 1996 Sep;23(9):766-76. doi: 10.1111/j.1440-1681.1996.tb01178.x. Clin Exp Pharmacol Physiol. 1996. PMID: 8911712 Review.
-
[Physiological basis for a cochlear prosthesis (author's transl)].Arch Otorhinolaryngol. 1979;223(1):77-137. doi: 10.1007/BF00455077. Arch Otorhinolaryngol. 1979. PMID: 383060 Review. German.
Cited by
-
Cochlear Implantation in Obliterated Cochlea: A Retrospective Analysis and Comparison between the IES Stiff Custom-Made Device and the Split-Array and Regular Electrodes.J Clin Med. 2022 Oct 16;11(20):6090. doi: 10.3390/jcm11206090. J Clin Med. 2022. PMID: 36294411 Free PMC article.
-
Does cochlear implantation and electrical stimulation affect residual hair cells and spiral ganglion neurons?Hear Res. 2007 Mar;225(1-2):60-70. doi: 10.1016/j.heares.2006.12.004. Epub 2006 Dec 15. Hear Res. 2007. PMID: 17258411 Free PMC article.
-
Effects of hearing preservation on psychophysical responses to cochlear implant stimulation.J Assoc Res Otolaryngol. 2010 Jun;11(2):245-65. doi: 10.1007/s10162-009-0194-7. Epub 2009 Nov 10. J Assoc Res Otolaryngol. 2010. PMID: 19902297 Free PMC article.
-
New criteria of indication and selection of patients to cochlear implant.Int J Otolaryngol. 2011;2011:573968. doi: 10.1155/2011/573968. Epub 2011 Oct 13. Int J Otolaryngol. 2011. PMID: 22013448 Free PMC article.
-
Cochlear Implantation: Long-Term Effect of Early Activation on Electrode Impedance.J Clin Med. 2024 Jun 3;13(11):3299. doi: 10.3390/jcm13113299. J Clin Med. 2024. PMID: 38893010 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Miscellaneous