Photic phenomena after phacoemulsification and posterior chamber lens implantation of various optic sizes
- PMID: 7932136
- DOI: 10.1016/s0886-3350(13)80182-4
Photic phenomena after phacoemulsification and posterior chamber lens implantation of various optic sizes
Abstract
Anecdotal reports and in vitro and clinical studies indicate that 5.0 mm x 6.0 mm ovoid posterior chamber lenses may have a higher incidence of photic phenomena, perhaps caused when the thicker truncated lens edge presents within the pupillary aperture. To evaluate these subjective phenomena, we gave a questionnaire to a random sample of patients who received one of three different poly(methyl methacrylate) (PMMA) posterior chamber lens optic styles (5.0 x 6.0 mm ovoid, 7.0 mm round, 5.5 mm round) placed in the bag. About 20% of all IOL groups reported photic phenomena, with symptoms similar between groups. The percentage reporting persistent phenomena was also comparable. We concluded that eyes in which any IOL optic is covered by the anterior capsular edge do not have a higher incidence of photic phenomena, which may instead result from the PMMA or vitreoretinal traction after cataract extraction.
Similar articles
-
Undesired light images associated with ovoid intraocular lenses.J Cataract Refract Surg. 1993 Nov;19(6):690-4. doi: 10.1016/s0886-3350(13)80336-7. J Cataract Refract Surg. 1993. PMID: 8271163
-
Visual disturbances associated with oval-optic poly(methyl methacrylate) and round-optic silicone intraocular lenses.J Cataract Refract Surg. 1994 May;20(3):295-8. doi: 10.1016/s0886-3350(13)80581-0. J Cataract Refract Surg. 1994. PMID: 8064606 Clinical Trial.
-
Posterior capsular opacification and intraocular lens decentration. Part I: Comparison of various posterior chamber lens designs implanted in the rabbit model.J Cataract Refract Surg. 1988 Nov;14(6):605-13. doi: 10.1016/s0886-3350(88)80027-0. J Cataract Refract Surg. 1988. PMID: 3230513
-
[Artificial intraocular lenses].Fortschr Ophthalmol. 1990;87 Suppl:S22-8. Fortschr Ophthalmol. 1990. PMID: 2083907 Review. German.
-
The Binkhorst Medal Lecture. Biologic relationship between poly(methyl methacrylate) intraocular lenses and uveal tissue.J Cataract Refract Surg. 1992 May;18(3):219-31. doi: 10.1016/s0886-3350(13)80897-8. J Cataract Refract Surg. 1992. PMID: 1593427 Review.
Cited by
-
A comparative clinical study of the visual results between three types of multifocal lenses.Graefes Arch Clin Exp Ophthalmol. 2010 Jan;248(1):133-40. doi: 10.1007/s00417-009-1177-4. Epub 2009 Sep 8. Graefes Arch Clin Exp Ophthalmol. 2010. PMID: 19763600 Clinical Trial.
-
Is the Memory Effect of the Blind Spot Involved in Negative Dysphotopsia after Cataract Surgery?J Ophthalmol. 2015;2015:786579. doi: 10.1155/2015/786579. Epub 2015 Sep 6. J Ophthalmol. 2015. PMID: 26425353 Free PMC article.
-
Efficacy of custom-made soft keratoconus lenses on corneal aberrations and photic phenomena in patients with keratoconus: a corneal topography imaging based study.Int J Ophthalmol. 2023 Jan 18;16(1):67-74. doi: 10.18240/ijo.2023.01.10. eCollection 2023. Int J Ophthalmol. 2023. PMID: 36659953 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical