Multistation multiparameter flow cytometry: a critical review and rationale
- PMID: 6185284
- DOI: 10.1002/cyto.990030402
Multistation multiparameter flow cytometry: a critical review and rationale
Abstract
The capacity for fluorescence excitation by beams of different wavelengths at separate points along the sample stream, and the capacity for computer analysis of multiparameter data thus obtained, are now available in flow cytometer/sorter systems from commercial producers. It is now readily apparent to most experienced users of flow cytometers that such multiparameter analysis offers the most convenient solution to the problem of characterizing subpopulations of cells within a mixed population. The use of multiple beams facilitates resolution of fluorescence signals from several probes within or upon a single cell and widens the range of analytical alternatives available to experimenters. This critical review discusses the history of the instrumentation, the parameters now measurable and the probes used for their measurement, and the methods for data analysis. Required sensitivity and precision are discussed, leading to the conclusion that many of the advantages of multistation, multiparameter flow cytometry can be made available in less complex and less costly instruments using less powerful sources and less elaborate computer hardware than are presently incorporated in commercial apparatus.
Similar articles
-
Flow cytometry instrumentation in research and clinical laboratories.Clin Lab Sci. 1993 May-Jun;6(3):167-73. Clin Lab Sci. 1993. PMID: 10146217 Review.
-
Multiple wavelength illumination in flow cytometry using a single arc lamp and a dispersing element.Cytometry. 1987 Sep;8(5):445-52. doi: 10.1002/cyto.990080503. Cytometry. 1987. PMID: 2444397
-
Three-color fluorescence measurements on single cells excited at three laser wavelengths.Cytometry. 1982 Jan;2(4):226-31. doi: 10.1002/cyto.990020405. Cytometry. 1982. PMID: 7056131
-
Data acquisition and control system for multiparameter cell sorting based on DEC LSI-11 microprocessor.Cytometry. 1982 May;2(6):383-9. doi: 10.1002/cyto.990020605. Cytometry. 1982. PMID: 7075399
-
The relevance of flow cytometry for biochemical analysis.IUBMB Life. 2001 Apr;51(4):231-9. doi: 10.1080/152165401753311771. IUBMB Life. 2001. PMID: 11569917 Review.
Cited by
-
Microfluidic flow cytometer for quantifying photobleaching of fluorescent proteins in cells.Anal Chem. 2012 May 1;84(9):3929-37. doi: 10.1021/ac202825z. Epub 2012 Apr 9. Anal Chem. 2012. PMID: 22424298 Free PMC article.
-
Free-Floating Mesothelial Cells in Pleural Fluid After Lung Surgery.Front Med (Lausanne). 2018 Apr 5;5:89. doi: 10.3389/fmed.2018.00089. eCollection 2018. Front Med (Lausanne). 2018. PMID: 29675416 Free PMC article.
-
Increase in total protein following infection of CV-1 cells with SV40 virus as assayed by flow cytometry.In Vitro Cell Dev Biol Anim. 1995 Nov;31(10):806-10. doi: 10.1007/BF02634124. In Vitro Cell Dev Biol Anim. 1995. PMID: 8564071
-
Monitoring of dynamic microbiological processes using real-time flow cytometry.PLoS One. 2013 Nov 14;8(11):e80117. doi: 10.1371/journal.pone.0080117. eCollection 2013. PLoS One. 2013. PMID: 24244624 Free PMC article.
-
Identification and isolation of endothelial cells based on their increased uptake of acetylated-low density lipoprotein.J Cell Biol. 1984 Dec;99(6):2034-40. doi: 10.1083/jcb.99.6.2034. J Cell Biol. 1984. PMID: 6501412 Free PMC article.
Publication types
MeSH terms
Substances
Grants and funding
LinkOut - more resources
Full Text Sources
Other Literature Sources