Simultaneous determination of total IgE and allergen-specific IgE in serum by the MAST chemiluminescent assay system
- PMID: 4028399
Simultaneous determination of total IgE and allergen-specific IgE in serum by the MAST chemiluminescent assay system
Abstract
We have developed a chemiluminescent immunoenzymometric system. The first commercial application of this chemiluminescent assay (CLA) is the measurement of total IgE and allergen-specific IgE in human serum. The CLA system is a second-generation adaptation of the MAST RIA allergy profiling system. The MAST CLA system assay protocol consists of three steps: overnight incubation of serum, a 4-h incubation with enzyme-labeled antibody, and a 30-min chemiluminescent reaction, which produces a visible image (immunograph) on high-speed Polaroid instant film. The densities of the bands produced on the film are quantified with an inexpensive microprocessor-controlled infrared transmittance densitometer. The novel luminogenic substrates used yield a constant light output for over 2 h with an intensity at least 10-fold greater than that of commercial chemiluminescent reagents. The MAST CLA system exhibits sensitivity, specificity, and precision equal to that of the MAST RIA system (r = 0.96 for 40 serum samples analyzed with 25 allergens). As many as 35 different allergens per sample can be quantified in a single assay. The MAST CLA system requires no standard curve or volume-dependent pipetting steps, incorporates both positive and negative controls for each sample, and quantifies allergen-specific IgE at picomolar concentrations.
Similar articles
-
Comparison of the MAST chemiluminescent assay system with RAST and skin tests in allergic children.Ann Allergy. 1993 Feb;70(2):153-7. Ann Allergy. 1993. PMID: 7679259
-
Inhalant allergens in asthmatic children in Taiwan: comparison evaluation of skin testing, radioallergosorbent test and multiple allergosorbent chemiluminescent assay for specific IgE.J Formos Med Assoc. 1992 Dec;91(12):1127-32. J Formos Med Assoc. 1992. PMID: 1363631 Clinical Trial.
-
Application of the MAST Immunodiagnostic System to the determination of allergen-specific IgE.Clin Chem. 1984 Sep;30(9):1467-72. Clin Chem. 1984. PMID: 6380812
-
Diagnostic reliability considerations of specific IgE determination.J Investig Allergol Clin Immunol. 1996 May-Jun;6(3):152-61. J Investig Allergol Clin Immunol. 1996. PMID: 8807505 Review.
-
Clinical laboratory assessment of immediate-type hypersensitivity.J Allergy Clin Immunol. 2010 Feb;125(2 Suppl 2):S284-96. doi: 10.1016/j.jaci.2009.09.055. J Allergy Clin Immunol. 2010. PMID: 20176264 Review.
Cited by
-
Surface-Enhanced Raman Scattering-Based Immunoassay Technologies for Detection of Disease Biomarkers.Biosensors (Basel). 2017 Jan 12;7(1):7. doi: 10.3390/bios7010007. Biosensors (Basel). 2017. PMID: 28085088 Free PMC article. Review.
-
Validity of MAST-CLA for diagnosis of arthropod allergy using receiver operating characteristic (ROC) analysis.Korean J Parasitol. 2007 Sep;45(3):239-43. doi: 10.3347/kjp.2007.45.3.239. Korean J Parasitol. 2007. PMID: 17876172 Free PMC article.
-
Validation and quality control of protein microarray-based analytical methods.Mol Biotechnol. 2008 Jan;38(1):19-31. doi: 10.1007/s12033-007-0066-5. Epub 2007 Aug 3. Mol Biotechnol. 2008. PMID: 18095188 Review.
-
Association between high serum total IgE levels and D11S97 on chromosome 11q13 in Japanese subjects.J Med Genet. 1995 May;32(5):363-9. doi: 10.1136/jmg.32.5.363. J Med Genet. 1995. PMID: 7616543 Free PMC article.
-
Simultaneous quantitation of specific IgE against 20 purified allergens in allergic patients sera by checkerboard immunoblotting (CBIB).J Clin Lab Anal. 1997;11(6):357-62. doi: 10.1002/(SICI)1098-2825(1997)11:6<357::AID-JCLA9>3.0.CO;2-2. J Clin Lab Anal. 1997. PMID: 9406057 Free PMC article.
MeSH terms
Substances
LinkOut - more resources
Other Literature Sources
Research Materials