Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2023 Apr:109:105345.
doi: 10.1016/j.parkreldis.2023.105345. Epub 2023 Feb 24.

Wearable sensors for assessing disease severity and progression in Progressive Supranuclear Palsy

Affiliations
Free article

Wearable sensors for assessing disease severity and progression in Progressive Supranuclear Palsy

Filomena Abate et al. Parkinsonism Relat Disord. 2023 Apr.
Free article

Abstract

Introduction: Progressive supranuclear palsy (PSP) is an atypical parkinsonism characterized by prominent gait and postural impairment. The PSP rating scale (PSPrs) is a clinician-administered tool to evaluate disease severity and progression. More recently, digital technologies have been used to investigate gait parameters. Therefore, object of this study was to implement a protocol using wearable sensors evaluating disease severity and progression in PSP.

Methods: Patients were evaluated with the PSPrs as well as with three wearable sensors located on the feet and lumbar area. Spearman coefficient was used to assess the relationship between PSPrs and quantitative measurements. Furthermore, sensor parameters were included in a multiple linear regression model to assess their ability in predicting the PSPrs total score and sub-scores. Finally, differences between baseline and three-month follow-up were calculated for PSPrs and each quantitative variable. The significance level in all analyses was set at ≤ 0.05.

Results: Fifty-eight evaluations from thirty-five patients were analyzed. Quantitative measurements showed multiple significant correlations with the PSPrs scores (r between 0.3 and 0.7; p < 0.05). Linear regression models confirmed the relationships. After three months visit, significant worsening from baseline was observed for cadence, cycle duration and PSPrs item 25, while PSPrs item 10 showed a significant improvement.

Conclusion: We propose wearable sensors can provide an objective, sensitive quantitative evaluation and immediate notification of gait changes in PSP. Our protocol can be easily introduced in outpatient and research settings as a complementary tool to clinical measures as well as an informative tool on disease severity and progression in PSP.

Keywords: Gait; PSP rating scale; Progressive supranuclear palsy; Wearable sensors.

PubMed Disclaimer

Conflict of interest statement

Declarations of competing interest None.

Similar articles

Cited by

Publication types

LinkOut - more resources