Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2019 Nov;39(6):566-571.
doi: 10.3343/alm.2019.39.6.566.

Comparison of Six Commercial Diagnostic Tests for the Detection of Dengue Virus Non-Structural-1 Antigen and IgM/IgG Antibodies

Affiliations
Comparative Study

Comparison of Six Commercial Diagnostic Tests for the Detection of Dengue Virus Non-Structural-1 Antigen and IgM/IgG Antibodies

Hyeyoung Lee et al. Ann Lab Med. 2019 Nov.

Abstract

ELISAs and rapid diagnostic tests (RDTs) are widely used for diagnosing dengue virus (DENV) infection. Using 138 single blood samples, we compared the ability to detect non-structural (NS)-1 antigen and anti-DENV IgM/IgG antibodies among (1) DENV Detect NS1 ELISA, DENV Detect IgM capture ELISA and DENV Detect IgG ELISA (InBios International, Inc.); (2) Anti-Dengue virus IgM Human ELISA and Anti-Dengue virus IgG Human ELISA (Abcam); (3) Dengue virus NS1 ELISA, Anti-Dengue virus ELISA (IgM) and Anti-Dengue virus ELISA (IgG) (Euroimmun); (4) Asan Easy Test Dengue NS1 Ag 100 and Asan Easy Test Dengue IgG/IgM (Asan Pharm); (5) SD BIOLINE Dengue Duo (Standard Diagnostics); and (6) Ichroma Dengue NS1 and Ichroma Dengue IgG/IgM (Boditech Med). For NS1 antigen detection, InBios and Euroimmun showed higher sensitivities (100%) than the RDTs (42.9-64.3%). All tests demonstrated variable sensitivities for IgM (38.1-90.5%) and IgG (65.7-100.0%). InBios and Boditech Med demonstrated higher sensitivity (95.6% and 88.2%, respectively) than the other tests for combined NS1 antigen and IgM antibody. Five NS1 antigen tests had good agreement (92.8-98.6%) without showing positivity for chikungunya. However, all IgG tests demonstrated potential false-positivity with variable ranges. Clinical laboratories should note performance variations across tests and potential cross-reactivity.

Keywords: Dengue virus; Diagnosis; ELISA; Performance; Rapid diagnostic tests.

PubMed Disclaimer

Conflict of interest statement

No potential conflicts of interest relevant to this article were reported.

Similar articles

Cited by

References

    1. World Health Organization. Dengue guidelines for diagnosis, treatment, prevention and control: new edition. World Health Organization; 2009. [Updated on Jan 2009]. http://www.who.int/iris/handle/10665/44188. - PubMed
    1. Suleman M, Faryal R, Alam MM, Sharif S, Shaukat S, Aamir UB, et al. Dengue virus serotypes circulating in Khyber Pakhtunkhwa Province, Pakistan, 2013-2015. Ann Lab Med. 2017;37:151–154. - PMC - PubMed
    1. Blacksell SD, Jarman RG, Bailey MS, Tanganuchitcharnchai A, Jenjaroen K, Gibbons RV, et al. Evaluation of six commercial point-of-care tests for diagnosis of acute dengue infections: the need for combining NS1 antigen and IgM/IgG antibody detection to achieve acceptable levels of accuracy. Clin Vaccine Immunol. 2011;18:2095–2101. - PMC - PubMed
    1. Fatima A, Wang J. Review: progress in the diagnosis of dengue virus infections and importance of point of care test: a review. Pak J Pharm Sci. 2015;28:271–280. - PubMed
    1. Dussart P, Labeau B, Lagathu G, Louis P, Nunes MR, Rodrigues SG, et al. Evaluation of an enzyme immunoassay for detection of dengue virus NS1 antigen in human serum. Clin Vaccine Immunol. 2006;13:1185–1189. - PMC - PubMed

Publication types