Biomaterial Influence on Intraocular Lens Performance: An Overview
- PMID: 29736282
- PMCID: PMC5874989
- DOI: 10.1155/2018/2687385
Biomaterial Influence on Intraocular Lens Performance: An Overview
Abstract
There is strong evidence that the IOL material is the factor having the greatest impact on posterior capsule opacification (PCO), anterior capsule opacification (ACO) development, and glistening formation after cataract surgery, even though there are other IOL features-such as haptic material and design and edge and optic design-that also have some influence. We reviewed the published literature describing the adverse events that are mainly related to the intraocular lens (IOL) material, such as PCO, ACO, and the subsequent capsule contraction, as well as glistening formation. The adverse events presented in this overview are the most common ones in clinical practice, and therefore, they are generally included in the clinical protocols for IOL evaluation.
Similar articles
-
Influence of three-piece and single-piece designs of two sharp-edge optic hydrophobic acrylic intraocular lenses on the prevention of posterior capsule opacification: a prospective, randomised, long-term clinical trial.Br J Ophthalmol. 2007 May;91(5):644-8. doi: 10.1136/bjo.2006.103648. Epub 2006 Nov 23. Br J Ophthalmol. 2007. PMID: 17124239 Free PMC article. Clinical Trial.
-
Effect of intraocular lens optic edge design and material on fibrotic capsule opacification and capsulorhexis contraction.J Cataract Refract Surg. 2004 Sep;30(9):1875-82. doi: 10.1016/j.jcrs.2004.01.042. J Cataract Refract Surg. 2004. PMID: 15342049 Clinical Trial.
-
[Comparison of postoperative results after implantation of hydrophilic acrylic or hydrophobic acrylic intraocular lens: data of one-year prospective clinical study].Medicina (Kaunas). 2008;44(12):936-43. Medicina (Kaunas). 2008. PMID: 19142051 Lithuanian.
-
An overview of the influence and design of biomaterial of the intraocular implant of the posterior capsule opacification.Rom J Ophthalmol. 2018 Jul-Sep;62(3):188-193. Rom J Ophthalmol. 2018. PMID: 30505987 Free PMC article. Review.
-
Effect of intraocular lens design on posterior capsule opacification.J Cataract Refract Surg. 2008 Nov;34(11):1976-85. doi: 10.1016/j.jcrs.2008.07.029. J Cataract Refract Surg. 2008. PMID: 19006748 Review.
Cited by
-
Current State of the Art and Next Generation of Materials for a Customized IntraOcular Lens according to a Patient-Specific Eye Power.Polymers (Basel). 2023 Mar 22;15(6):1590. doi: 10.3390/polym15061590. Polymers (Basel). 2023. PMID: 36987370 Free PMC article. Review.
-
Posterior Capsular Outcomes of Pediatric Cataract Surgery With In-The-Bag Intraocular Lens Implantation.Front Pediatr. 2022 Apr 8;10:827084. doi: 10.3389/fped.2022.827084. eCollection 2022. Front Pediatr. 2022. PMID: 35463896 Free PMC article.
-
Randomized multicenter trial to assess posterior capsule opacification and glistenings in two hydrophobic acrylic intraocular lenses.Sci Rep. 2023 Feb 17;13(1):2822. doi: 10.1038/s41598-023-29855-8. Sci Rep. 2023. PMID: 36805494 Free PMC article. Clinical Trial.
-
Costs and Healthcare Resource Utilization Associated with Posterior Capsule Opacification After Cataract Surgery with Five Different Intraocular Lenses: An Economic Analysis for Spain.Clin Ophthalmol. 2022 Mar 31;16:993-1001. doi: 10.2147/OPTH.S349003. eCollection 2022. Clin Ophthalmol. 2022. PMID: 35386615 Free PMC article.
-
Risk factors for the occurrence of visual-threatening posterior capsule opacification.J Transl Med. 2019 Jun 20;17(1):209. doi: 10.1186/s12967-019-1956-6. J Transl Med. 2019. PMID: 31221170 Free PMC article.
References
-