Assessment of Healthcare Worker Protocol Deviations and Self-Contamination During Personal Protective Equipment Donning and Doffing
- PMID: 28606192
- PMCID: PMC6263164
- DOI: 10.1017/ice.2017.121
Assessment of Healthcare Worker Protocol Deviations and Self-Contamination During Personal Protective Equipment Donning and Doffing
Abstract
OBJECTIVE To evaluate healthcare worker (HCW) risk of self-contamination when donning and doffing personal protective equipment (PPE) using fluorescence and MS2 bacteriophage. DESIGN Prospective pilot study. SETTING Tertiary-care hospital. PARTICIPANTS A total of 36 HCWs were included in this study: 18 donned/doffed contact precaution (CP) PPE and 18 donned/doffed Ebola virus disease (EVD) PPE. INTERVENTIONS HCWs donned PPE according to standard protocols. Fluorescent liquid and MS2 bacteriophage were applied to HCWs. HCWs then doffed their PPE. After doffing, HCWs were scanned for fluorescence and swabbed for MS2. MS2 detection was performed using reverse transcriptase PCR. The donning and doffing processes were videotaped, and protocol deviations were recorded. RESULTS Overall, 27% of EVD PPE HCWs and 50% of CP PPE HCWs made ≥1 protocol deviation while donning, and 100% of EVD PPE HCWs and 67% of CP PPE HCWs made ≥1 protocol deviation while doffing (P=.02). The median number of doffing protocol deviations among EVD PPE HCWs was 4, versus 1 among CP PPE HCWs. Also, 15 EVD PPE protocol deviations were committed by doffing assistants and/or trained observers. Fluorescence was detected on 8 EVD PPE HCWs (44%) and 5 CP PPE HCWs (28%), most commonly on hands. MS2 was recovered from 2 EVD PPE HCWs (11%) and 3 CP PPE HCWs (17%). CONCLUSIONS Protocol deviations were common during both EVD and CP PPE doffing, and some deviations during EVD PPE doffing were committed by the HCW doffing assistant and/or the trained observer. Self-contamination was common. PPE donning/doffing are complex and deserve additional study. Infect Control Hosp Epidemiol 2017;38:1077-1083.
Conflict of interest statement
Comment in
-
Bacteriophage M13 May Be Used for the Assessment of Viral Transfer during Doffing of Ebola-Level Personal Protective Equipment.Infect Control Hosp Epidemiol. 2018 Jun;39(6):762-763. doi: 10.1017/ice.2018.74. Epub 2018 Apr 15. Infect Control Hosp Epidemiol. 2018. PMID: 29655392 No abstract available.
Similar articles
-
Personal protective equipment for preventing highly infectious diseases due to exposure to contaminated body fluids in healthcare staff.Cochrane Database Syst Rev. 2020 May 15;5(5):CD011621. doi: 10.1002/14651858.CD011621.pub5. Cochrane Database Syst Rev. 2020. PMID: 32412096 Free PMC article.
-
Personal protective equipment for preventing highly infectious diseases due to exposure to contaminated body fluids in healthcare staff.Cochrane Database Syst Rev. 2016 Apr 19;4:CD011621. doi: 10.1002/14651858.CD011621.pub2. Cochrane Database Syst Rev. 2016. Update in: Cochrane Database Syst Rev. 2019 Jul 01;7:CD011621. doi: 10.1002/14651858.CD011621.pub3. PMID: 27093058 Free PMC article. Updated. Review.
-
Assessment of Self-Contamination During Removal of Personal Protective Equipment for Ebola Patient Care.Infect Control Hosp Epidemiol. 2016 Oct;37(10):1156-61. doi: 10.1017/ice.2016.169. Epub 2016 Aug 1. Infect Control Hosp Epidemiol. 2016. PMID: 27477451
-
Self-contamination during doffing of personal protective equipment by healthcare workers to prevent Ebola transmission.Antimicrob Resist Infect Control. 2018 Dec 22;7:157. doi: 10.1186/s13756-018-0433-y. eCollection 2018. Antimicrob Resist Infect Control. 2018. PMID: 30607244 Free PMC article.
-
Which type of personal protective equipment (PPE) and which method of donning or doffing PPE carries the least risk of infection for healthcare workers?Evid Based Dent. 2020 Jun;21(2):74-76. doi: 10.1038/s41432-020-0097-3. Evid Based Dent. 2020. PMID: 32591668 Free PMC article. Review.
Cited by
-
Assessing the Physiological Relevance of Cough Simulators for Respiratory Droplet Dispersion.J Clin Med. 2020 Sep 17;9(9):3002. doi: 10.3390/jcm9093002. J Clin Med. 2020. PMID: 32957639 Free PMC article.
-
Management of SARS-CoV-2 Omicron Variant Community Screenings in Shanghai, China: A Cross-Sectional Study.Risk Manag Healthc Policy. 2023 Feb 2;16:111-120. doi: 10.2147/RMHP.S392697. eCollection 2023. Risk Manag Healthc Policy. 2023. PMID: 36755747 Free PMC article.
-
Use of personal protective equipment to protect against respiratory infections in Pakistan: A systematic review.J Infect Public Health. 2020 Mar;13(3):385-390. doi: 10.1016/j.jiph.2020.02.032. Epub 2020 Mar 4. J Infect Public Health. 2020. PMID: 32146139 Free PMC article.
-
Virtual tabletop simulations for primary care pandemic preparedness and response.BMJ Simul Technol Enhanc Learn. 2021 Jul;7(6):487-493. doi: 10.1136/bmjstel-2020-000854. Epub 2021 Apr 13. BMJ Simul Technol Enhanc Learn. 2021. PMID: 34422296 Free PMC article.
-
COVID - 19 case study in emergency medicine preparedness and response: from personal protective equipment to delivery of care.Dis Mon. 2020 Sep;66(9):101060. doi: 10.1016/j.disamonth.2020.101060. Epub 2020 Jul 27. Dis Mon. 2020. PMID: 32800348 Free PMC article. Review. No abstract available.
References
Publication types
MeSH terms
Grants and funding
LinkOut - more resources
Full Text Sources
Other Literature Sources
Miscellaneous