Variability and uncertainty of 18F-FDG PET imaging protocols for assessing inflammation in atherosclerosis: suggestions for improvement
- PMID: 25722452
- DOI: 10.2967/jnumed.114.142596
Variability and uncertainty of 18F-FDG PET imaging protocols for assessing inflammation in atherosclerosis: suggestions for improvement
Abstract
PET with (18)F-FDG shows promise for the evaluation of metabolic activities in atherosclerotic plaques. Although recommendations regarding the acquisition and measurement protocols to be used for (18)F-FDG PET imaging of atherosclerosis inflammation have been published, there is no consensus regarding the most appropriate protocols, and the image reconstruction approach has been especially overlooked. Given the small size of the targeted lesions, the reconstruction and measurement methods might strongly affect the results. We determined the differences in results due to the protocol variability and identified means of increasing the measurement reliability.
Methods: An extensive literature search was performed to characterize the variability in atherosclerosis imaging and quantification protocols. Highly realistic simulations of atherosclerotic carotid lesions based on real patient data were designed to determine how the acquisition and processing protocol parameters affected the measured values.
Results: In 49 articles, we identified 53 different acquisition protocols, 51 reconstruction protocols, and 46 quantification methods to characterize atherosclerotic lesions from (18)F-FDG PET images. The most important parameters affecting the measurement accuracy were the number of iterations used for reconstruction and the postfiltering applied to the reconstructed images, which could together make the measured standardized uptake values (SUVs) vary by a factor greater than 3. Image sampling, acquisition duration, and metrics used for the measurements also affected the results to a lesser extent (SUV varying by a factor of 1.3 at most). For an acceptable SUV variability, the lowest bias in SUV was observed using an 8-min acquisition per bed position; ordered-subset expectation maximization reconstruction with at least 120 maximum likelihood expectation maximization equivalent iterations, including a point spread function model using a 1 mm(3) voxel size; and no postfiltering. Because of the partial-volume effect, measurement bias remained greater than 60%. The use and limitations of the target-to-blood activity ratio metrics are also presented and discussed.
Conclusion: (18)F-FDG PET protocol harmonization is needed in atherosclerosis imaging. Optimized protocols can significantly reduce the measurement errors in wall activity estimates, but PET systems with higher spatial resolution and advanced partial-volume corrections will be required to accurately assess plaque inflammation from (18)F-FDG PET.
Keywords: 18F-FDG PET; atherosclerosis; partial-volume effect; vascular lesions.
© 2015 by the Society of Nuclear Medicine and Molecular Imaging, Inc.
Comment in
-
PET assessment of vascular inflammation and atherosclerotic plaques: SUV or TBR?J Nucl Med. 2015 Apr;56(4):503-4. doi: 10.2967/jnumed.115.154385. Epub 2015 Feb 26. J Nucl Med. 2015. PMID: 25722451 No abstract available.
Similar articles
-
Atherosclerosis inflammation imaging with 18F-FDG PET: carotid, iliac, and femoral uptake reproducibility, quantification methods, and recommendations.J Nucl Med. 2008 Jun;49(6):871-8. doi: 10.2967/jnumed.107.050294. Epub 2008 May 15. J Nucl Med. 2008. PMID: 18483100
-
Quantification of atherosclerotic plaque activity and vascular inflammation using [18-F] fluorodeoxyglucose positron emission tomography/computed tomography (FDG-PET/CT).J Vis Exp. 2012 May 2;(63):e3777. doi: 10.3791/3777. J Vis Exp. 2012. PMID: 22588186 Free PMC article.
-
Higher reliability of 18F-FDG target background ratio compared to standardized uptake value in vulnerable carotid plaque detection: a pilot study.Ann Nucl Med. 2014 Jul;28(6):571-9. doi: 10.1007/s12149-014-0850-9. Epub 2014 Apr 16. Ann Nucl Med. 2014. PMID: 24737136
-
[¹⁸F]-fluorodeoxyglucose PET imaging of atherosclerosis.PET Clin. 2015 Jan;10(1):1-7. doi: 10.1016/j.cpet.2014.09.001. Epub 2014 Nov 22. PET Clin. 2015. PMID: 25455876 Review.
-
Assessment of atherosclerosis in large vessel walls: A comprehensive review of FDG-PET/CT image acquisition protocols and methods for uptake quantification.J Nucl Cardiol. 2015 Jun;22(3):468-79. doi: 10.1007/s12350-015-0069-8. Epub 2015 Apr 1. J Nucl Cardiol. 2015. PMID: 25827619 Review.
Cited by
-
Characterising polymyalgia rheumatica on whole-body 18F-FDG PET/CT: an atlas.Rheumatol Adv Pract. 2024 Feb 20;8(1):rkae003. doi: 10.1093/rap/rkae003. eCollection 2024. Rheumatol Adv Pract. 2024. PMID: 38375531 Free PMC article. Review.
-
Effect of Statin Therapy on Arterial Wall Inflammation Based on 18F-FDG PET/CT: A Systematic Review and Meta-Analysis of Interventional Studies.J Clin Med. 2019 Jan 18;8(1):118. doi: 10.3390/jcm8010118. J Clin Med. 2019. PMID: 30669380 Free PMC article. Review.
-
Imaging findings and clinical relevance of 68Ga-Pentixafor PET in atherosclerosis: a systematic review.BMC Med Imaging. 2023 Oct 26;23(1):166. doi: 10.1186/s12880-023-01134-y. BMC Med Imaging. 2023. PMID: 37884885 Free PMC article.
-
Carotid Plaque Positron Emission Tomography Imaging and Cerebral Ischemic Disease.Stroke. 2019 Aug;50(8):2072-2079. doi: 10.1161/STROKEAHA.118.023987. Epub 2019 Jul 5. Stroke. 2019. PMID: 31272325 Free PMC article.
-
Constrictive Pericarditis: A Medical or Surgical Disease?J Cardiovasc Imaging. 2019 Jul;27(3):178-186. doi: 10.4250/jcvi.2019.27.e28. Epub 2019 Apr 30. J Cardiovasc Imaging. 2019. PMID: 31161752 Free PMC article. Review.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical