Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2014 May;53(2):273-82.
doi: 10.1007/s00411-014-0525-x. Epub 2014 Mar 7.

Automated analysis of the cytokinesis-block micronucleus assay for radiation biodosimetry using imaging flow cytometry

Affiliations

Automated analysis of the cytokinesis-block micronucleus assay for radiation biodosimetry using imaging flow cytometry

M A Rodrigues et al. Radiat Environ Biophys. 2014 May.

Abstract

The cytokinesis-block micronucleus (CBMN) assay is employed in biological dosimetry to determine the dose of radiation to an exposed individual from the frequency of micronuclei (MN) in binucleated lymphocyte cells. The method has been partially automated for the use in mass casualty events, but it would be advantageous to further automate the method for increased throughput. Recently, automated image analysis has been successfully applied to the traditional, slide-scoring-based method of the CBMN assay. However, with the development of new technologies such as the imaging flow cytometer, it is now possible to adapt this microscope-based assay to an automated imaging flow cytometry method. The ImageStream(X) is an imaging flow cytometer that has adequate sensitivity to quantify radiation doses larger than 1 Gy while adding the increased throughput of traditional flow cytometry. The protocol and analysis presented in this work adapts the CBMN assay for the use on the ImageStream(X). Ex vivo-irradiated whole blood samples cultured for CBMN were analyzed on the ImageStream(X), and preliminary results indicate that binucleated cells and MN can be identified, imaged and enumerated automatically by imaging flow cytometry. Details of the method development, gating strategy and the dose response curve generated are presented and indicate that adaptation of the CBMN assay for the use with imaging flow cytometry has potential for high-throughput analysis following a mass casualty radiological event.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Health Phys. 2010 Feb;98(2):209-17 - PubMed
    1. Mutat Res. 1997 Aug 1;392(1-2):109-15 - PubMed
    1. Int J Radiat Biol. 2010 Jan;86(1):2-11 - PubMed
    1. Mutat Res. 1985 Feb-Apr;147(1-2):29-36 - PubMed
    1. Mutat Res. 2011 Oct 1;715(1-2):72-8 - PubMed

MeSH terms

LinkOut - more resources