Review
. 2014 Mar;16(3):459.
doi: 10.1007/s11886-013-0459-y.

The potential of FDG PET/CT for early diagnosis of cardiac device and prosthetic valve infection before morphologic damages ensue

Affiliations
Review

The potential of FDG PET/CT for early diagnosis of cardiac device and prosthetic valve infection before morphologic damages ensue

Wengen Chen et al. Curr Cardiol Rep. 2014 Mar.

Abstract

Diagnosis of cardiac mechanical device or prosthesis valve infection, and more importantly accurate localization of the infection site, such as defibrillator pocket, pacemaker lead, annular or peri-annular valve ring abscesses remain clinically challenging. Inconclusive diagnosis can lead to delayed antibiotic therapy, device extraction or surgical intervention, which may have dire consequences to the patient. Among patients with suspected cardiac mechanical device or prosthetic valve infection, recent publications advocate the use of (18)F-fluoro-2-deoxyglucose positron emission tomography computed tomography (FDG PET/CT), particularly when anatomy based imaging studies, such as echocardiography or CT, are uncertain or negative. A potential advantage of FDG PET/CT is in its detection of inflammatory cells early in the infection process, before morphologic damages ensue. However, there are many unanswered questions in the literature. There is a need for standardization amongst the various imaging studies, such as dietary preparation, duration and timing of image acquisition, image processing with and without CT attenuation correction, and more importantly image interpretation criteria. The answer for these issues awaits well designed, prospective studies.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Heart Rhythm. 2010 Aug;7(8):1043-7 - PubMed
    1. Heart Rhythm. 2011 Sep;8(9):1478-81 - PubMed
    1. J Am Coll Cardiol. 2012 May 1;59(18):1616-25 - PubMed
    1. Circulation. 2005 Jun 14;111(23):e394-434 - PubMed
    1. J Am Coll Cardiol. 2012 May 1;59(18):1626-8 - PubMed

MeSH terms

Substances

LinkOut - more resources