Meta-analysis: ARFI elastography versus transient elastography for the evaluation of liver fibrosis
- PMID: 23859217
- DOI: 10.1111/liv.12240
Meta-analysis: ARFI elastography versus transient elastography for the evaluation of liver fibrosis
Abstract
Aims: This meta-analysis aims to compare the diagnostic performance of acoustic radiation force impulse (ARFI) elastography and transient elastography (TE) in the assessment of liver fibrosis using liver biopsy (LB) as 'gold-standard'.
Methods: PubMed, Medline, Lilacs, Scopus, Ovid, EMBASE, Cochrane and Medscape databases were searched for all studies published until 31 May 2012 that evaluated the liver stiffness by means of ARFI, TE and LB. Information abstracted from each study according to a fixed protocol included study design and methodological characteristics, patient characteristics, interventions, outcomes and missing outcome data.
Results: Thirteen studies (11 full-length articles and 2 abstracts) including 1163 patients with chronic hepatopathies were included in the analysis. Inability to obtain reliable measurements was more than thrice as high for TE as that of ARFI (6.6% vs. 2.1%, P < 0.001). For detection of significant fibrosis, (F ≥ 2) the summary sensitivity (Se) was 0.74 (95% CI: 0.66-0.80) and specificity (Sp) was 0.83 (95% CI: 0.75-0.89) for ARFI, while for TE the Se was 0.78 (95% CI: 0.72-0.83) and Sp was 0.84 (95% CI: 0.75-0.90). For the diagnosis of cirrhosis, the summary Se was 0.87 (95% CI: 0.79-0.92) and Sp was 0.87 (95% CI: 0.81-0.91) for ARFI elastography, and, respectively, 0.89 (95% CI: 0.80-0.94) and 0.87 (95% CI: 0.82-0.91) for TE. The diagnostic odds ratio of ARFI and TE did not differ significantly in the detection of significant fibrosis [mean difference in rDOR = 0.27 (95% CI: 0.69-0.14)] and cirrhosis [mean difference in rDOR = 0.12 (95% CI: 0.29-0.52)].
Conclusion: Acoustic radiation force impulse elastography seems to be a good method for assessing liver fibrosis, and shows higher rate of reliable measurements and similar predictive value to TE for significant fibrosis and cirrhosis.
Keywords: ARFI; acoustic radiation force impulse elastography; fibroscan®; liver fibrosis; liver stiffness; transient elastography.
© 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Similar articles
-
Acoustic radiation force impulse elastography as compared to transient elastography and liver biopsy in patients with chronic hepatopathies.Ultraschall Med. 2011 Jan;32 Suppl 1:S46-52. doi: 10.1055/s-0029-1245360. Epub 2010 Jul 5. Ultraschall Med. 2011. PMID: 20603783
-
Liver fibrosis: noninvasive assessment with acoustic radiation force impulse elastography--comparison with FibroScan M and XL probes and FibroTest in patients with chronic liver disease.Radiology. 2013 Oct;269(1):283-92. doi: 10.1148/radiol.13122208. Epub 2013 Apr 29. Radiology. 2013. PMID: 23630312
-
Acoustic radiation force impulse elastography and serum fibrosis markers in chronic hepatitis C.Scand J Gastroenterol. 2014 Aug;49(8):986-92. doi: 10.3109/00365521.2014.909528. Epub 2014 Apr 17. Scand J Gastroenterol. 2014. PMID: 24742130
-
Acoustic Radiation Force Impulse (ARFI) Elastography for non‑invasive evaluation of hepatic fibrosis in chronic hepatitis B and C patients: a systematic review and meta-analysis.Med Ultrason. 2017 Jan 31;19(1):23-31. doi: 10.11152/mu-942. Med Ultrason. 2017. PMID: 28180193 Review.
-
Acoustic Radiation Force Impulse Elastography for the Non-Invasive Evaluation of Hepatic Fibrosis in Non-Alcoholic Fatty Liver Disease Patients: A Systematic Review & Meta-Analysis.PLoS One. 2015 Jul 1;10(7):e0127782. doi: 10.1371/journal.pone.0127782. eCollection 2015. PLoS One. 2015. PMID: 26131717 Free PMC article. Review.
Cited by
-
Ultrasound Elastography and MR Elastography for Assessing Liver Fibrosis: Part 2, Diagnostic Performance, Confounders, and Future Directions.AJR Am J Roentgenol. 2015 Jul;205(1):33-40. doi: 10.2214/AJR.15.14553. Epub 2015 Apr 23. AJR Am J Roentgenol. 2015. PMID: 25905762 Free PMC article.
-
Interpretable machine learning models based on shear-wave elastography radiomics for predicting cardiovascular disease in diabetic kidney disease patients.J Diabetes Investig. 2024 Nov;15(11):1637-1650. doi: 10.1111/jdi.14294. Epub 2024 Aug 22. J Diabetes Investig. 2024. PMID: 39171653 Free PMC article.
-
Spectrum of liver diseases in patients referred for Fibroscan: A single center experience in the Middle East.Ann Med Surg (Lond). 2020 Jul 25;57:166-170. doi: 10.1016/j.amsu.2020.07.040. eCollection 2020 Sep. Ann Med Surg (Lond). 2020. PMID: 32774848 Free PMC article.
-
Virtual Touch™ Quantification to Diagnose and Monitor Liver Fibrosis in Hepatitis B and Hepatitis C: A NICE Medical Technology Guidance.Appl Health Econ Health Policy. 2017 Apr;15(2):139-154. doi: 10.1007/s40258-016-0277-7. Appl Health Econ Health Policy. 2017. PMID: 27601240 Free PMC article. Review.
-
Transient elastography (FibroScan(®)) with controlled attenuation parameter in the assessment of liver steatosis and fibrosis in patients with nonalcoholic fatty liver disease - Where do we stand?World J Gastroenterol. 2016 Aug 28;22(32):7236-51. doi: 10.3748/wjg.v22.i32.7236. World J Gastroenterol. 2016. PMID: 27621571 Free PMC article. Review.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical