Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2013 May;27(3):186-94.
doi: 10.1002/jcla.21582. Epub 2013 Feb 25.

Importance of collection methods and stability of oral fluid samples for hepatitis B surface antigen detection

Affiliations

Importance of collection methods and stability of oral fluid samples for hepatitis B surface antigen detection

Letícia de Paula Scalioni et al. J Clin Lab Anal. 2013 May.

Abstract

Background: Oral fluid (OF) sample collection and stability for HBsAg detection are not fully established. This study aims to investigate the applicability of OF collectors and sample stability for Hepatitis B virus surface antigen detection.

Methods: Paired serum and OF samples were obtained from 191 individuals, and Chembio (Chembio Diagnostic System, USA) and Salivette (Sarstedt, Germany) devices were used for OF collection. Two HBsAg enzyme immunoassays (EIAs) were used (HBsAg One kit, Radim, Rome, Italy and ETI-MAK-4, DiaSorin, Vercelli, Italy) to determine the most efficient method according OF collector. Sample volume, incubation time, and cutoff (CO) value were evaluated. The stability of OF samples was determined under different environmental conditions.

Results: Chembio samples analyzed using DiaSorin EIA without modification of the manufacturer's instructions, demonstrated a sensitivity of 95.24% and a specificity of 100%. Salivette samples analyzed with Radim EIA with receiver operating characteristic (ROC) curve for calculating the CO showed a sensitivity of 78.26% and a specificity of 89.88%. HBsAg was detected in Chembio and Salivette samples under different environmental conditions, but the Chembio samples were the most stable.

Conclusions: Both collectors can be used for HBsAg detection in OF samples, but some modifications of commercial EIAs should be incorporated for Salivette device. OF samples were reliably stable and could be stored for up to 90 days at 2-8°C.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Aspinall EJ, Hawkins G, Fraser A, Hutchinson SJ, Goldberg D. Hepatitis B prevention, diagnosis, treatment and care: A review. Occup Med 2011;61:531–540. - PubMed
    1. World Health Organization (WHO) . Hepatitis B. 2011. Available from: http://www.who.int/csr/disease/hepatitis/whocdscsrlyo20022/en/ Accessed on 2011 July 25.
    1. Elgouhari HM, Abu‐Rajab Tamimi TI, Carey WD. Hepatitis B virus infection: Understanding its epidemiology, course, and diagnosis. Cleve Clin J Med 2008;75:881–889. - PubMed
    1. Ott JJ, Stevens GA, Groeger J, Wiersma ST. Global epidemiology of hepatitis B virus infection: New estimates of age‐specific HBsAg seroprevalence and endemicity. Vaccine 2012;30:2212–2219. - PubMed
    1. Cruz HM, da Silva EF, Villela‐Nogueira CA, et al. Evaluation of saliva specimens as an alternative sampling method to detect hepatitis B surface antigen. J Clin Lab Anal 2011;25:134–141. - PMC - PubMed

Publication types

MeSH terms

Substances