Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2012 Dec 14:1268:157-65.
doi: 10.1016/j.chroma.2012.09.102. Epub 2012 Oct 22.

Fast separation of triterpenoids by supercritical fluid chromatography/evaporative light scattering detector

Affiliations

Fast separation of triterpenoids by supercritical fluid chromatography/evaporative light scattering detector

E Lesellier et al. J Chromatogr A. .

Abstract

The screening of plant material, the chemical composition, the abundance and the biological activity of triterpenoids are of a major economical importance. The classical analytical methods, such as TLC, GC, and HPLC are either little resolutive, or require derivatization steps, or fail in sensitivity. The supercritical fluid chromatography/evaporative light scattering detector (SFC/ELSD) coupling provides high resolution, fast analysis and higher responses for the analysis of triterpenoids. After the initial screening of seven stationary phases to select the well suited one, analytical conditions (modifier percentage, from 10 to 3%; backpressure (from 12 to 18 MPa) and temperature (from 15 to 25 °C) were studied to improve the separation, and ELSD detection of a standard mixture composed of 8 triterpenoids (oleanolic acid, erythrodiol, β-amyrin, ursolic acid, uvaol, betulinic acid, betulin, lupeol). Applied to apple pomace extracts, this method allows the separation of about 15 triterpenoid compounds, in less than 20 min, with isocratic conditions. Moreover, the ELSD response is dramatically higher than the one provided by UV detection, and avoids derivatization steps. An attempt to identify some compounds was done by collecting chromatographic peaks and further analyzing them with mass spectrometry. Complete identification or molecular formula could be proposed for 11 compounds. However, due to the presence of position and orientation isomers the absolute identification remains difficult, despite some retention rules deduced from the standard analysis.

PubMed Disclaimer

Similar articles

Cited by

Publication types

MeSH terms

LinkOut - more resources