The effects of sonographic and demographic features and needle size on obtaining adequate cytological material in sonography-guided fine-needle aspiration biopsy of thyroid nodules
- PMID: 22956413
- DOI: 10.1007/s12020-012-9784-y
The effects of sonographic and demographic features and needle size on obtaining adequate cytological material in sonography-guided fine-needle aspiration biopsy of thyroid nodules
Abstract
The aim of this study is to investigate the effects of the sonographic characteristics of the nodule, demographic features of patient, and nodule size and needle size used for sampling, on obtaining adequate cytological material (CM) in thyroid fine-needle aspiration biopsy (FNAB). We performed 270 FNAB between September 2010 and June 2012. Size, echogenicity, and localization of all nodules were evaluated by ultrasonography (US) before the biopsy. Nodules were grouped as <1, 1-3, and >3 cm according to their size and as hypoechoic, isoechoic, hyperechoic, or heterogeneous according to their US characteristics. 20-, 22-, and 24-G needles were used for the biopsies. Different sonographic characteristics of the nodules did not affect the needle selection. All specimens were classified as adequate or inadequate CM by a cytopathologist. A total of 270 nodules were biopsied, 184 (68.1 %) specimens were considered as adequate CM and 86 (31.9 %) specimens were considered as inadequate CM. Patient age and the presence of heterogeneous echogenicity were found to have prognostic significance in univariate analysis (p < 0.05). In a multivariate logistic regression model with forward stepwise method, advanced age (p = 0.001, OR = 1.042, 95CI 1.018-1.068) and heterogeneous echogenicity (p = 0.017, OR = 1.955, 95CI 1.129-3.385) remained associated with an increased risk of inadequate CM obtainment after adjustment for other potential confounders (nodule size >3 cm and needle size 20-G usage) and variables found to be statistically significant in univariate analysis. Non-diagnostic FNAB remains a significant problem in the evaluation of thyroid nodules and can be as high as 30 %. Inadequate CM rates for elderly patients and heterogeneous nodules were significantly higher than that for other factors. The nodule size and needle size used for sampling did not affect the adequacy of FNAB.
Similar articles
-
Potential causes for obtaining non-diagnostic results from fine needle aspiration biopsy of thyroid nodules.Radiol Med. 2016 Jun;121(6):510-4. doi: 10.1007/s11547-016-0624-7. Epub 2016 Feb 16. Radiol Med. 2016. PMID: 26883230
-
Sonographically guided fine-needle biopsy of thyroid nodules: the effects of nodule characteristics, sampling technique, and needle size on the adequacy of cytological material.Clin Radiol. 2007 Aug;62(8):798-803. doi: 10.1016/j.crad.2007.01.024. Epub 2007 May 7. Clin Radiol. 2007. PMID: 17604771
-
Comparison of Cytological Adequacy between 23- and 25-Gauge in Ultrasound-Guided Fine-Needle Aspiration of Thyroid Nodules: A Single-Center Prospective Study.Acta Cytol. 2024;68(2):121-127. doi: 10.1159/000538290. Epub 2024 Apr 10. Acta Cytol. 2024. PMID: 38599193
-
A Literature Review of Factors Associated With Pain From Fine Needle Aspiration Biopsy of Thyroid Nodules.Endocr Pract. 2022 Jun;28(6):628-636. doi: 10.1016/j.eprac.2022.03.007. Epub 2022 Mar 16. Endocr Pract. 2022. PMID: 35306164 Review.
-
Acute transient thyroid swelling after fine-needle aspiration biopsy: A case report of a rare complication and a literature review.Diagn Cytopathol. 2022 Jul;50(7):E193-E197. doi: 10.1002/dc.24948. Epub 2022 Mar 2. Diagn Cytopathol. 2022. PMID: 35234360 Free PMC article. Review.
Cited by
-
Potential causes for obtaining non-diagnostic results from fine needle aspiration biopsy of thyroid nodules.Radiol Med. 2016 Jun;121(6):510-4. doi: 10.1007/s11547-016-0624-7. Epub 2016 Feb 16. Radiol Med. 2016. PMID: 26883230
-
Patient's comfort with and tolerability of thyroid core needle biopsy.Endocrine. 2014 Feb;45(1):79-83. doi: 10.1007/s12020-013-9979-x. Epub 2013 May 15. Endocrine. 2014. PMID: 23673868
-
Fine Needle Aspiration in the Investigation of Thyroid Nodules.Dtsch Arztebl Int. 2016 May 20;113(20):353-9. doi: 10.3238/arztebl.2016.0353. Dtsch Arztebl Int. 2016. PMID: 27294815 Free PMC article. Review.
-
Effect of needle gauge on thyroid FNA diagnostic rate.Endocrine. 2021 Dec;74(3):625-631. doi: 10.1007/s12020-021-02797-9. Epub 2021 Jun 19. Endocrine. 2021. PMID: 34146249
-
Importance of FNA Technique for Decreasing Non-diagnostic Rates in Thyroid Nodules.Head Neck Pathol. 2018 Jun;12(2):160-165. doi: 10.1007/s12105-017-0844-8. Epub 2017 Aug 17. Head Neck Pathol. 2018. PMID: 28819755 Free PMC article.
References
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources