Semi-automated direct elution of dried blood spots for the quantitative determination of guanfacine in human blood
- PMID: 22793029
- DOI: 10.4155/bio.12.111
Semi-automated direct elution of dried blood spots for the quantitative determination of guanfacine in human blood
Abstract
Background: Direct analysis of dried blood spot (DBS) samples was investigated using a prototype semi-automated robotic device that allows the direct elution of sample spots from a DBS paper card to an online SPE cartridge. The eluted SPE samples were analyzed with high-performance LC-MS/MS.
Results: A LLOQ of 0.01 ng/ml was achieved with a linear calibration range from 0.01 to 25 ng/ml. Optimal performance data were obtained from spotting the internal standard solution on the card before blood spotting. Internal standard addition from the system injector loop produced intra-assay inaccuracy of -9.0-7.3% and precision of 1.3-8.2%, and inter-assay inaccuracy of -3.5-3.9% and precision of 4.4-8.7%.
Conclusion: Results demonstrated the feasibility of a semi-automated online rapid direct elution method that avoids manual extraction for DBS sample analysis using the online DBS-SPE system coupled to LC-MS/MS.
Similar articles
-
The use of a membrane filtration device to form dried plasma spots for the quantitative determination of guanfacine in whole blood.Rapid Commun Mass Spectrom. 2012 May 30;26(10):1208-12. doi: 10.1002/rcm.6212. Rapid Commun Mass Spectrom. 2012. PMID: 22499196
-
Dried blood spots as a sampling technique for the quantitative determination of guanfacine in clinical studies.Bioanalysis. 2011 Nov;3(22):2501-14. doi: 10.4155/bio.11.262. Bioanalysis. 2011. PMID: 22122599
-
Simultaneous LC-MS/MS quantitation of acetaminophen and its glucuronide and sulfate metabolites in human dried blood spot samples collected by subjects in a pilot clinical study.Bioanalysis. 2012 Jun;4(12):1429-43. doi: 10.4155/bio.12.119. Bioanalysis. 2012. PMID: 22793028
-
The application of fully automated dried blood spot analysis for liquid chromatography-tandem mass spectrometry using the CAMAG DBS-MS 500 autosampler.Clin Biochem. 2020 Aug;82:33-39. doi: 10.1016/j.clinbiochem.2020.02.007. Epub 2020 Feb 19. Clin Biochem. 2020. PMID: 32087137 Review.
-
Emerging liquid chromatography-mass spectrometry technologies improving dried blood spot analysis.Expert Rev Proteomics. 2014 Aug;11(4):425-30. doi: 10.1586/14789450.2014.904204. Epub 2014 Apr 3. Expert Rev Proteomics. 2014. PMID: 24697571 Review.
Cited by
-
The Use of Dried Blood Spots for the Quantification of Antihypertensive Drugs.Int J Anal Chem. 2018 Aug 1;2018:3235072. doi: 10.1155/2018/3235072. eCollection 2018. Int J Anal Chem. 2018. PMID: 30154849 Free PMC article. Review.
-
Method development and validation of Guanfacine in rat plasma by liquid chromatography-tandem mass spectrometry: Application to a pharmacokinetic study.J Pharm Anal. 2013 Dec;3(6):472-480. doi: 10.1016/j.jpha.2013.04.006. Epub 2013 Jun 27. J Pharm Anal. 2013. PMID: 29403858 Free PMC article.
-
Advantages and Challenges of Dried Blood Spot Analysis by Mass Spectrometry Across the Total Testing Process.EJIFCC. 2016 Dec 1;27(4):288-317. eCollection 2016 Dec. EJIFCC. 2016. PMID: 28149263 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources