Comparison of the performance of direct fluorescent antibody staining, a point-of-care rapid antigen test and virus isolation with that of RT-PCR for the detection of novel 2009 influenza A (H1N1) virus in respiratory specimens
- PMID: 20203216
- DOI: 10.1099/jmm.0.017244-0
Comparison of the performance of direct fluorescent antibody staining, a point-of-care rapid antigen test and virus isolation with that of RT-PCR for the detection of novel 2009 influenza A (H1N1) virus in respiratory specimens
Abstract
Although infections with the novel pandemic 2009 influenza A (H1N1) virus (A/H1N1/2009) appeared to be relatively mild during the first summer of circulation ('off season'), there has been significant morbidity and hospitalization and several fatal cases. Thus, rapid detection of A/H1N1/2009 is crucial for efficient treatment and infection control measures. In contrast to seasonal influenza, where point-of-care (POC) rapid antigen tests and direct fluorescent antibody (DFA) staining ensure rapid detection, diagnosis of A/H1N1/2009 has so far been based on RT-PCR. This study retrospectively compared the performance of the Quidel QuickVue POC test, DFA staining and virus isolation with that of RT-PCR for A/H1N1/2009 detection in 526 respiratory specimens collected during the first wave of the outbreak from May to September 2009. A/H1N1/2009 was detected in 9.1% (48/526) of samples. One hundred and thirty-seven of the A/H1N1/2009 PCR-negative samples were additionally tested using a RealAccurate Respiratory RT-PCR panel, revealing other respiratory viruses (mainly entero/rhino- and adenoviruses) in 42.3% (58/137). All methods analysed detected A/H1N1/2009 with excellent specificity but different sensitivities (POC test: 18.2%; DFA staining: 38.7%; virus isolation: 45.7%). Therefore, the POC test was not suitable for diagnosis, detecting A/H1N1/2009 only if present in high concentrations (corresponding median Ct value=19.0; range=16.5-21.4). DFA staining was also able to detect A/H1N1/2009 in specimens with a lower virus concentration (median Ct value=24.0; range=16.5-29.8). Virus isolation, which was positive after a median time of 7.5 days, was too time-consuming. In summary, DFA staining is superior to POC testing and may be appropriate for patients expected to have a rather high level of virus replication. Nevertheless, in DFA-negative specimens, A/H1N1/2009 should be excluded by RT-PCR.
Similar articles
-
Public hospital-based laboratory experience during an outbreak of pandemic influenza A (H1N1) virus infections.J Clin Microbiol. 2010 Apr;48(4):1189-94. doi: 10.1128/JCM.01657-09. Epub 2010 Feb 10. J Clin Microbiol. 2010. PMID: 20147645 Free PMC article.
-
Evaluation of QuickVue influenza A+B rapid test for detection of pandemic influenza A/H1N1 2009.J Clin Virol. 2010 Jun;48(2):120-2. doi: 10.1016/j.jcv.2010.03.010. Epub 2010 Apr 15. J Clin Virol. 2010. PMID: 20399140
-
Validity of two rapid point of care influenza tests and direct fluorecence assay in comparison of real time PCR for swine of origin Influenza virus.J Infect Public Health. 2011 Mar;4(1):7-11. doi: 10.1016/j.jiph.2010.10.004. Epub 2011 Feb 4. J Infect Public Health. 2011. PMID: 21338954
-
Detection methods for influenza A H1N1 virus with special reference to biosensors: a review.Biosci Rep. 2020 Feb 28;40(2):BSR20193852. doi: 10.1042/BSR20193852. Biosci Rep. 2020. PMID: 32016385 Free PMC article. Review.
-
Tools to detect influenza virus.Yonsei Med J. 2013 May 1;54(3):560-6. doi: 10.3349/ymj.2013.54.3.560. Yonsei Med J. 2013. PMID: 23549796 Free PMC article. Review.
Cited by
-
Comparison of four multiplex PCR assays for the detection of viral pathogens in respiratory specimens.J Virol Methods. 2013 Aug;191(2):118-21. doi: 10.1016/j.jviromet.2013.04.005. Epub 2013 Apr 11. J Virol Methods. 2013. PMID: 23583489 Free PMC article.
-
Evaluating an app-guided self-test for influenza: lessons learned for improving the feasibility of study designs to evaluate self-tests for respiratory viruses.BMC Infect Dis. 2021 Jun 29;21(1):617. doi: 10.1186/s12879-021-06314-1. BMC Infect Dis. 2021. PMID: 34187397 Free PMC article.
-
SARS-CoV-2 detecting rapid metasurface-based sensor.Diam Relat Mater. 2023 Feb;132:109644. doi: 10.1016/j.diamond.2022.109644. Epub 2022 Dec 23. Diam Relat Mater. 2023. PMID: 36575667 Free PMC article.
-
rapidSTRIPE H1N1 test for detection of the pandemic swine origin influenza A (H1N1) virus.J Clin Microbiol. 2011 Apr;49(4):1591-3. doi: 10.1128/JCM.02563-10. Epub 2011 Jan 19. J Clin Microbiol. 2011. PMID: 21248098 Free PMC article.
-
Plasmonic Fluorescence Sensors in Diagnosis of Infectious Diseases.Biosensors (Basel). 2024 Mar 2;14(3):130. doi: 10.3390/bios14030130. Biosensors (Basel). 2024. PMID: 38534237 Free PMC article. Review.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical