Solid-phase enzyme immunoassay for herpes simplex virus
- PMID: 198493
- DOI: 10.1093/infdis/136.supplement_2.s304
Solid-phase enzyme immunoassay for herpes simplex virus
Abstract
An enzyme immunoassay was used for the rapid detection of herpes simplex virus type 1 (HSV-1). The test utilized specific antibodies to HSV-1 attached to a solid phase. A laboratory preparation of HSV-1 was detectable in amounts of greater than or equal to 50 50% tissue culture-infective doses by this method. Tests performed with clinical samples indicated a specificity of 95%. The sensitivity appeared to depend on the length of time the samples were stored. When samples were stored frozen for three to six months, the sensitivity was 46% of that of tissue culture isolations performed when the samples were first collected. The sensitivity was 89% in comparison with attempts at tissue culture reisolation with the same samples at the time of enzyme immunoassay. The immunoassay also detected HSV in seven of 10 positive samples that were stored frozen for no more than two weeks before testing.
Similar articles
-
Comparison of enzyme immunoassay, shell vial culture, and conventional cell culture for the rapid detection of herpes simplex virus.Diagn Microbiol Infect Dis. 1990 May-Jun;13(3):241-4. doi: 10.1016/0732-8893(90)90066-5. Diagn Microbiol Infect Dis. 1990. PMID: 2166633
-
Multicenter clinical evaluation of the Du Pont Herpchek HSV ELISA, a new rapid diagnostic test for the direct detection of herpes simplex virus.Adv Exp Med Biol. 1990;263:71-6. doi: 10.1007/978-1-4613-0601-6_6. Adv Exp Med Biol. 1990. PMID: 2162132
-
Detection of herpes simplex virus by the Kodak SureCell Herpes Test.J Clin Microbiol. 1990 Sep;28(9):2117-9. doi: 10.1128/jcm.28.9.2117-2119.1990. J Clin Microbiol. 1990. PMID: 2172300 Free PMC article.
-
Tests for detecting herpes simplex virus and varicella-zoster virus infections.Dermatol Clin. 1994 Jan;12(1):51-68. Dermatol Clin. 1994. PMID: 8143385 Review.
-
Light microscopy, culture, molecular, and serologic methods for detection of herpes simplex virus.J Clin Microbiol. 2014 Jan;52(1):2-8. doi: 10.1128/JCM.01966-13. Epub 2013 Oct 16. J Clin Microbiol. 2014. PMID: 24131689 Free PMC article. Review.
Cited by
-
Comparison of chemiluminescence and absorptiometry in enzyme immunoassays for protein quantification.Experientia. 1982 Mar 15;38(3):304-6. doi: 10.1007/BF01949356. Experientia. 1982. PMID: 6176465
-
Enzyme-linked immunosorbent assay for detection of antibodies to influenza A and B and parainfluenza type 1 in sera of patients.J Clin Microbiol. 1978 Dec;8(6):648-56. doi: 10.1128/jcm.8.6.648-656.1978. J Clin Microbiol. 1978. PMID: 217892 Free PMC article.
-
Solid-phase enzyme-linked immunosorbent assay for detection of hepatitis A virus.J Clin Microbiol. 1978 Sep;8(3):277-82. doi: 10.1128/jcm.8.3.277-282.1978. J Clin Microbiol. 1978. PMID: 212452 Free PMC article.
-
Endotoxin contamination of enzyme conjugates used in enzyme-linked immunosorbent assays.J Clin Microbiol. 1983 Jun;17(6):1050-3. doi: 10.1128/jcm.17.6.1050-1053.1983. J Clin Microbiol. 1983. PMID: 6348074 Free PMC article.
-
Enzyme-linked immunoassays for the detection of microbial antigens and their antibodies.Adv Appl Microbiol. 1986;31:271-92. doi: 10.1016/s0065-2164(08)70445-3. Adv Appl Microbiol. 1986. PMID: 3521211 Free PMC article. Review.
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources