Testing an OMERACT MRI scoring system for peripheral psoriatic arthritis in cross-sectional and longitudinal settings
- PMID: 19671818
- DOI: 10.3899/jrheum.090351
Testing an OMERACT MRI scoring system for peripheral psoriatic arthritis in cross-sectional and longitudinal settings
Abstract
Objective: Magnetic resonance imaging (MRI) is increasingly used to measure articular inflammation and damage in patients with psoriatic arthritis (PsA). We evaluated the reliability of a new OMERACT PsA MRI scoring system, PsAMRIS, in PsA fingers.
Methods: In 2 separate studies, MRI scans were obtained from patients with clinical evidence of synovitis or dactylitis of the fingers. For the first cross-sectional study, images were obtained at one timepoint. For the second longitudinal study, images were obtained at 2 timepoints, 6 weeks apart. Scans were scored using PsAMRIS in an international multireader setting, for synovitis, tenosynovitis, periarticular inflammation, bone edema, bone erosions, and bone proliferation.
Results: Global status scores from both datasets revealed moderate to high reliability for scoring most features, although reliability was poor for periarticular inflammation in the cross-sectional study. Change scores that reflected inflammatory activity also exhibited moderate to good reliability in the longitudinal exercise, despite there being very little absolute change in MRI synovitis or tenosynovitis observed in this dataset. At the distal interphalangeal joints, reliability for change scores was acceptable only for synovitis and tenosynovitis.
Conclusion: Further development and testing of the PsAMRIS is planned to improve its performance as a clinical and research tool to identify and measure pathology in peripheral joint PsA.
Similar articles
-
The OMERACT Psoriatic Arthritis Magnetic Resonance Imaging Score (PsAMRIS) is reliable and sensitive to change: results from an OMERACT workshop.J Rheumatol. 2011 Sep;38(9):2034-8. doi: 10.3899/jrheum.110420. J Rheumatol. 2011. PMID: 21885513 Clinical Trial.
-
Developing a magnetic resonance imaging scoring system for peripheral psoriatic arthritis.J Rheumatol. 2007 Apr;34(4):859-61. J Rheumatol. 2007. PMID: 17407240
-
Feasibility and reproducibility of the PsAMRIS-H score for psoriatic arthritis in low-field-strength dedicated extremity magnetic resonance imaging.Scand J Rheumatol. 2013;42(5):379-82. doi: 10.3109/03009742.2013.783105. Epub 2013 May 28. Scand J Rheumatol. 2013. PMID: 23713482
-
The MRI view of synovitis and tenosynovitis in inflammatory arthritis: implications for diagnosis and management.Ann N Y Acad Sci. 2009 Feb;1154:21-34. doi: 10.1111/j.1749-6632.2009.04382.x. Ann N Y Acad Sci. 2009. PMID: 19250228 Review.
-
The OMERACT psoriatic arthritis magnetic resonance imaging scoring system (PsAMRIS): definitions of key pathologies, suggested MRI sequences, and preliminary scoring system for PsA Hands.J Rheumatol. 2009 Aug;36(8):1816-24. doi: 10.3899/jrheum.090352. J Rheumatol. 2009. PMID: 19671819
Cited by
-
Implementation of the OMERACT Psoriatic Arthritis Magnetic Resonance Imaging Scoring System in a randomized phase IIb study of abatacept in psoriatic arthritis.Rheumatology (Oxford). 2022 Nov 2;61(11):4305-4313. doi: 10.1093/rheumatology/keac073. Rheumatology (Oxford). 2022. PMID: 35137002 Free PMC article. Clinical Trial.
-
Psoriatic Dactylitis: Current Perspectives and New Insights in Ultrasonography and Magnetic Resonance Imaging.J Clin Med. 2021 Jun 12;10(12):2604. doi: 10.3390/jcm10122604. J Clin Med. 2021. PMID: 34204773 Free PMC article. Review.
-
Introduction of a Simplified Psoriatic Arthritis Magnetic Resonance Imaging Score (sPsAMRIS): A Potential Tool for Treatment Monitoring in Peripheral Psoriatic Arthritis.Diagnostics (Basel). 2020 Dec 15;10(12):1093. doi: 10.3390/diagnostics10121093. Diagnostics (Basel). 2020. PMID: 33333853 Free PMC article.
-
The comparison of efficacy of different imaging techniques (conventional radiography, ultrasonography, magnetic resonance) in assessment of wrist joints and metacarpophalangeal joints in patients with psoriatic arthritis.Pol J Radiol. 2013 Jan;78(1):18-29. doi: 10.12659/PJR.883764. Pol J Radiol. 2013. PMID: 23494635 Free PMC article.
-
Reliability and responsiveness of the Juvenile Arthritis MRI Scoring (JAMRIS) system for the knee.Eur Radiol. 2013 Apr;23(4):1075-83. doi: 10.1007/s00330-012-2684-y. Epub 2012 Oct 20. Eur Radiol. 2013. PMID: 23085866
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical
Research Materials
Miscellaneous