A review of locking compression plate biomechanics and their advantages as internal fixators in fracture healing
- PMID: 17904257
- DOI: 10.1016/j.clinbiomech.2007.08.004
A review of locking compression plate biomechanics and their advantages as internal fixators in fracture healing
Abstract
Metallic implants are often involved in the open reduction and internal fixation of fractures. Open reduction and internal fixation is commonly used in cases of trauma when the bone cannot be healed using external methods such as casting. The locking compression plate combines the conventional screw hole, which uses non-locking screws, with a locking screw hole, which uses locking head screws. This allows for more versatility in the application of the plate. There are many factors which affect the functionality of the plate (e.g., screw placement, screw choice, length of plate, distance from bone, etc.). This paper presents a review of the literature related to the biomechanics of locking compression plates and their use as internal fixators in fracture healing. Furthermore, this paper also addresses the materials used for locking compression plates and their mechanical behavior, parameters that control the overall success, as well as inherent bone quality results.
Similar articles
-
Overview of the locking compression plate and its clinical applications in fracture healing.J Surg Orthop Adv. 2008 Winter;17(4):271-81. J Surg Orthop Adv. 2008. PMID: 19138501 Review.
-
Flexible fixation and fracture healing: do locked plating 'internal fixators' resemble external fixators?J Orthop Trauma. 2011 Feb;25 Suppl 1:S15-20. doi: 10.1097/BOT.0b013e31820711d3. J Orthop Trauma. 2011. PMID: 21248555 Review.
-
A biomechanic comparison of an internal radiocarpal-spanning 2.4-mm locking plate and external fixation in a model of distal radius fractures.J Hand Surg Am. 2006 Dec;31(10):1578-86. doi: 10.1016/j.jhsa.2006.09.014. J Hand Surg Am. 2006. PMID: 17145376
-
Analysis of the mechanical properties of locking plates with and without screw hole inserts.Orthopedics. 2011 Jan 3;34(1):19. doi: 10.3928/01477447-20101123-13. Orthopedics. 2011. PMID: 21210620
-
Biomechanical testing of the locking compression plate: when does the distance between bone and implant significantly reduce construct stability?Injury. 2007 Mar;38(3):358-64. doi: 10.1016/j.injury.2006.08.058. Epub 2007 Feb 12. Injury. 2007. PMID: 17296199
Cited by
-
Biodegradable Orthopedic Magnesium-Calcium (MgCa) Alloys, Processing, and Corrosion Performance.Materials (Basel). 2012 Jan 9;5(1):135-155. doi: 10.3390/ma5010135. Materials (Basel). 2012. PMID: 28817036 Free PMC article. Review.
-
An Outline on the Advancements in Surgical Management of Osteoporosis-Associated Fractures.Cureus. 2024 Jun 26;16(6):e63226. doi: 10.7759/cureus.63226. eCollection 2024 Jun. Cureus. 2024. PMID: 39070522 Free PMC article. Review.
-
Effect of plate working length on plate stiffness and cyclic fatigue life in a cadaveric femoral fracture gap model stabilized with a 12-hole 2.4 mm locking compression plate.BMC Vet Res. 2013 Jun 24;9:125. doi: 10.1186/1746-6148-9-125. BMC Vet Res. 2013. PMID: 23800317 Free PMC article.
-
Minimally invasive plate osteosynthesis for the treatment of sternal fracture in the lower chest: a case report.J Int Med Res. 2019 Aug;47(8):4033-4038. doi: 10.1177/0300060519865074. Epub 2019 Jul 31. J Int Med Res. 2019. PMID: 31364423 Free PMC article.
-
Biomechanical investigation of an alternative concept to angular stable plating using conventional fixation hardware.BMC Musculoskelet Disord. 2010 May 21;11:95. doi: 10.1186/1471-2474-11-95. BMC Musculoskelet Disord. 2010. PMID: 20492707 Free PMC article.