Fellow-eye comparison of posterior capsule opacification rates after implantation of 1CU accommodating and AcrySof MA30 monofocal intraocular lenses
- PMID: 17321391
- DOI: 10.1016/j.jcrs.2006.10.056
Fellow-eye comparison of posterior capsule opacification rates after implantation of 1CU accommodating and AcrySof MA30 monofocal intraocular lenses
Abstract
Purpose: To measure posterior capsule opacification (PCO) and neodymium:YAG (Nd:YAG) capsulotomy rates between the AcrySof MA30 intraocular lens (IOL) (Alcon) and the 1CU IOL (HumanOptics) in a fellow-eye comparison.
Setting: Ophthalmology Department, St. Thomas' Hospital, London, United Kingdom.
Methods: Thirty patients who had bilateral cataract surgery with a 1CU IOL prospectively randomly allocated to 1 eye and an AcrySof MA30 monofocal IOL to the other eye were examined. Best corrected distance visual acuity was recorded using the Early Treatment Diabetic Retinopathy Study logMAR chart. Digital retroillumination images of the posterior capsule were taken with the pupil dilated and analyzed with POCO software.
Results: Eyes with the 1CU IOL had significantly higher PCO rates than eyes with the MA30 IOL at all time points. By 2 years after surgery, 50% of eyes with a 1CU IOL had required Nd:YAG capsulotomy compared with no eyes with an MA30 IOL. There was no significant difference in visual acuity at any time point when post Nd:YAG capsulotomy was taken in to account.
Conclusions: The 1CU IOL has 4 broad optic-haptic junctions where the square-edged barrier is breached; this appeared to allow passage of lens epithelial cells, leading to an increase in PCO. However, the increased PCO cannot be attributed to this alone as the 1CU is hydrophilic, a factor known to be associated with higher PCO rates.
Similar articles
-
Intraocular lens optic edge design for the prevention of posterior capsule opacification after cataract surgery.Cochrane Database Syst Rev. 2021 Aug 16;8(8):CD012516. doi: 10.1002/14651858.CD012516.pub2. Cochrane Database Syst Rev. 2021. PMID: 34398965 Free PMC article. Review.
-
Fellow-eye comparison of posterior capsule opacification with AcrySof SN60AT and AF-1 YA-60BB blue-blocking intraocular lenses.J Cataract Refract Surg. 2008 Sep;34(9):1489-94. doi: 10.1016/j.jcrs.2008.05.024. J Cataract Refract Surg. 2008. PMID: 18721708 Clinical Trial.
-
Posterior capsule opacification and neodymium:YAG laser capsulotomy rates with a round-edged silicone and a sharp-edged hydrophobic acrylic intraocular lens 10 years after surgery.J Cataract Refract Surg. 2009 Mar;35(3):459-65. doi: 10.1016/j.jcrs.2008.11.044. J Cataract Refract Surg. 2009. PMID: 19251138
-
Posterior capsule opacification after implantation of CeeOn Edge 911A, PhacoFlex SI-40NB, and AcrySof MA60BM lenses: one-year results of an intraindividual comparison multicenter study.J Cataract Refract Surg. 2004 May;30(5):978-85. doi: 10.1016/j.jcrs.2003.09.052. J Cataract Refract Surg. 2004. PMID: 15130632 Clinical Trial.
-
Posterior capsule opacification: a review of the aetiopathogenesis, experimental and clinical studies and factors for prevention.Indian J Ophthalmol. 2004 Jun;52(2):99-112. Indian J Ophthalmol. 2004. PMID: 15283214 Review.
Cited by
-
Clinical application of accommodating intraocular lens.Int J Ophthalmol. 2018 Jun 18;11(6):1028-1037. doi: 10.18240/ijo.2018.06.22. eCollection 2018. Int J Ophthalmol. 2018. PMID: 29977819 Free PMC article. Review.
-
Budget impact analysis of lens material on the posterior capsule opacification (PCO) as a complication after the cataract surgery.Cost Eff Resour Alloc. 2020 Jun 16;18:19. doi: 10.1186/s12962-020-00214-y. eCollection 2020. Cost Eff Resour Alloc. 2020. PMID: 32549794 Free PMC article.
-
Intraocular lens optic edge design for the prevention of posterior capsule opacification after cataract surgery.Cochrane Database Syst Rev. 2021 Aug 16;8(8):CD012516. doi: 10.1002/14651858.CD012516.pub2. Cochrane Database Syst Rev. 2021. PMID: 34398965 Free PMC article. Review.
-
Effect of hydrophobic acrylic versus hydrophilic acrylic intraocular lens on posterior capsule opacification: meta-analysis.PLoS One. 2013 Nov 5;8(11):e77864. doi: 10.1371/journal.pone.0077864. eCollection 2013. PLoS One. 2013. PMID: 24223736 Free PMC article.
-
Hydrophobic versus hydrophilic acrylic intraocular lens on posterior capsule opacification: a Meta-analysis.Int J Ophthalmol. 2022 Jun 18;15(6):997-1004. doi: 10.18240/ijo.2022.06.19. eCollection 2022. Int J Ophthalmol. 2022. PMID: 35814890 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical